Err | 056
Cause:
The "Wire-end check" option has detected the end of the wire electrode
Remedy:
Insert a new wirespool and feed the wire electrode into the hosepack;
acknowledge Err | 056 by pressing the Store button
Cause:
Additional fan filter of the VR 1500 - 11 / 12 / 30 is contaminated
air supply for the additional fan is no longer sufficient to cool the power elec-
tronics
the power electronics temperature switch has tripped
Remedy:
Clean filter or replace;
acknowledge Err | 056 by pressing the Store button
Cause:
Excessive ambient temperature on the VR 1500 - 11 / 12 / 30
Remedy:
Reduce ambient temperature
if necessary position and operate welding machine at a cooler location;
acknowledge Err | 056 by pressing the Store button
Cause:
Excessive motor current on the VR 1500 - 11 / 12 / 30, e.g. due to wire feed
problems or an adequately dimensioned wire-feed unit
Remedy:
Check wire feed conditions, rectify errors;
acknowledge Err | 056 by pressing the Store button
Cause:
VR 1530 wire-feed unit cover open or interlock release handles not snapped
into place
Remedy:
Close VR 1530 wire-feed unit cover properly
acknowledge Err | 056 by pressing the Store button
Err | 062
"E62" is displayed on the TP 08 remote control at the same time
Cause:
Overheating of TP 08 remote control
Remedy:
Allow TP 08 remote control to cool down
Err | 069
Cause:
Illegal mode change during welding (e.g. changing from a MIG/MAG job to a
TIG job)
Remedy:
Re-start welding action
Err |70.X
Cause:
Fault in digital gas sensor
Err 70.1 ... Gas sensor not found
Err 70.2 ... No gas
Err 70.3 ... Calibration error
Err 70.4 ... Solenoid valve faulty
Err 70.5 ... Solenoid valve not found
Remedy:
Check gas supply
Err |71.X
Set limits have been exceeded or have not been reached.
Cause:
Err 71.1 ... Current limit exceeded
Err 71.2 ... Current limit not reached
Err 71.3 ... Voltage limit exceeded
Err 71.4 ... Voltage limit not reached
Remedy:
Check quality of weld seam
169