Fronius TransSynergic 5000 Operating Instructions & Spare Parts page 139

Mig/mag power source
Hide thumbs Also See for TransSynergic 5000:
Table of Contents

Advertisement

I-S
I (current) - Starting current
Unit
Setting range
Factory setting
SL
Slope
Unit
Setting range
Factory setting
I-E
I (current) - End - Final current
Unit
Setting range
Factory setting
FAC
Reset power source to factory setting
Press and hold down the Store button for 2 s to restore the factory settings
when "PrG" appears on the digital display, the power source has been reset
NOTE! When the power source is reset, all the customised settings in the Setup
menu are lost.
When the power source is reset, jobs are not deleted but are retained in the memory. The
functions in the second level of the Setup menu (2nd) are also not deleted. Exception: Ig-
nition time-out welding parameter (ito).
2nd
Second level of the Setup menu (see "Setup menu - level 2")
t-S
time - Starting current - Starting current duration
Unit
Setting range
Factory setting
t-E
time - End current - Final current duration
Unit
Setting range
Factory setting
% (of starting current)
0 - 200
135
s
0.1 - 9.9
1.0
% (of starting current)
0 - 200
50
s
OFF or 0.1 - 9.9
OFF
s
OFF or 0.1 - 9.9
OFF
137