HIKVISION DS-3WF03C-D User Manual page 38

Outdoor video wireless network bridge
Table of Contents

Advertisement

User Manual of DS-3WF03C-D
Outdoor Video Wireless Network Bridge
Ping Watchdog: The ping watchdog sets the DS-3WF03C-D Device to continuously ping a
user-defined IP address (for example, it can be the IP address of the AP the Client is
connecting to). If it is unable to ping under the user defined constraints, the DS-
3WF03C-D device will automatically reboot. It is highly recommended that users enable
this feature at the side of "Station" and disable this feature at the side of "Access Point".
Ping Interval: Specify time interval (in seconds) between the ping requests are sent by
the Ping Watchdog
Ping IP Address: Specify an IP address of the target which will be monitored by Ping
Watchdog. If this feature is enabled at the side of "Station", Ping IP Address should be
the IP address of the AP the Client is connecting to.
Startup Delay: Specify initial time delay (in seconds) until first ping request is sent by the
Ping Watchdog
Ping Failure: Specify the number of ping replies. If the specified number of ping replies
is not received continuously, the Ping Watchdog will reboot the device.
If users want to modify the parameters of Ping Watchdog, please disable it first and then
apply. When the web page shows that Ping Watchdog is really disabled, users can now
re-enable it with modified parameters.
Telnet/Syslog: When telnet is enabled, the user can input command "Telnet
192.168.1.36" in the DOS window of Windows XP or Windows 7 PC, and then telnet to
the DS-3WF03C-D and manipulate the DS-3WF03C-D device. When telnet is disabled,
this operation is disabled.
When Syslog is enabled, and the System Log server's IP is also set here, the log
information will be output to the Syslog server automatically.
NTP/SNMP: If this NTP server is set, and the DS-3WF03C-D device can access to this NTP
server. DS-3WF03C-D device automatically calibrate the time and date information with
the NTP server and show the time information in the Status page.
When SNMP is enabled, use can check the working condition and information of the DS-
3WF03C-D device.
Spectral Scanning: Spectral scanning function can view around the 20MHz bandwidth
frequency of the use situation; this can help you configure the device to avoid busy
frequency. If you run the spectral scanning, you cannot do any configuration operations
on the device page. If you want to configure the device again, you only need to click the
exit button in the spectral scanning web page to exit.