CONTROL SYSTEM
12.13 On Unit Indicators and Controls
STAND BY
INDICATOR
OPERATION
INDICATOR
MODE BUTTON
(Cool, Heat, SB)
12-30
Lights up when the Air Conditioner is connected to power and
ready to receive the R/C commands
Blinks continuously in case of any thermistor failure.
Lights up during operation.
Blinks for 300 ms, to announce that a R/C infrared signal has
been received and stored.
Blinks continuously during
OCT High Pressure Protection Mode
ICT High Pressure Protection Mode
Deicing in Heating Mode
Water Over Flow in ECC Model
Use to cycle the operation mode of the A/C unit among COOL,
HEAT and SB modes, without using the R/C.
Every time this switch is pressed, the next operation mode is
selected, in this order :
SB
Cool Mode
Press this button continuously for 5 sec or more to start the
Diagnostic Mode.
Revision
Heat Mode
SB
0