4
Parts of the Meter
ITEM
4
5
4-1
DESCRIPTION
/MAX BUTTON
During run mode, pressing this button displays the "HI RDG"
(peak reading) value that has occurred up to the moment the
'MAX' button is pressed. This peak reading flashes, to
distinguish its value from the current readings. Since this is a
dynamic peak reading, the value will change if the value
increases while reviewing it.
To return to display of the current readings without resetting the
peak-value memory to zero (0), press the 'MAX' button once
again.
To reset the peak-value memory (start a new peak determining
period), press the 'RESET' button once.
During the configuration mode, the 'MAX' button is used to
change the numerical value of the flashing digit displayed. For
submenu items, such as "L1C.1=0", pressing the 'MAX' button
toggles the choice from "0" to "1".
The meter allows rapid changes of a displayed numerical value
by making "0" the first value to occur when the 'MAX' button is
pressed. After that, the numbers increase to "9" and then roll
over to "0" again. A negative ("–") symbol may be displayed in
the most significant digit (i.e. the digit at the far left such as
shown here "–.8.8.8.8.8.")
In the SETPT (SETPOINT) mode (SP1, SP2, etc), pressing the
'MAX' button causes the flashing digit to increment by 1 from 0
to 9.
/MIN BUTTON
During run mode, pressing the 'MIN' button recalls the "LO
RDG" (valley reading) measured since the last press of the
'RESET' button. This lowest value flashes, to distinguish it from
the current process display. Since this is a dynamic valley
reading, the value will change if the value decreases while
reviewing it.