MDS D139: Display of speed relative to data volume (read/write)
Figure 4-16
4.4.4
MDS D160 with RF310R, RF340R/RF350R and RF380R
The following table is used to calculate the curves.
The indicated speeds are applicable for operation without presence check.
Operating distance
(S
a
SIMATIC RF300
System Manual, 11/2009 - Zwischenstand 17.09.2009, A5E01642529-04
4.4 Dependence of the volume of data on the transponder speed with ISO tags
MDS D139 with RF310R, RF340R/RF350R and RF380R
)
RF310R
RF340R/RF350R
20 mm
RF300 system planning
RF380R
40 mm
57