Rf300 - Siemens SIMATIC RF300 System Manual

Simatic sensors
Hide thumbs Also See for SIMATIC RF300:
Table of Contents

Advertisement

Table 4- 4
RF380R reader transmission window and read/write distance
S
:
Operating distance between transponder and reader
a
S
Limit distance (maximum clear distance between upper surface of the reader and the transponder, at which the
g
transmission can still function under normal conditions)
L
Length of a transmission window in the x direction
x
The length L
is valid for the calculation. At S
x
L
Length of a transmission window in the y direction
y
The length L
is valid for the calculation. At S
y
M
Field centerpoint
The transponder can be used as soon as the intersection (SP) of the transponder enters the
area of the transmission window.
SIMATIC RF300
System Manual, 11/2009 - Zwischenstand 17.09.2009, A5E01642529-04
, the field length increases from L
a,min
, the field length increases from L
a,min
RF300 system planning
4.1 Fundamentals of application planning
to L
.
x
max
to L
.
y
y max
31