Rf340R - Siemens SIMATIC Ident RF340R02 System Manual

Table of Contents

Advertisement

4.3.4.2

RF340R

With RF300 transponders
Table 4- 37
Transponder
RF320T
RF330T
RF340T
RF350T
RF360T
RF370T
RF380T
Mounting the transponder on or in metal is only possible with the appropriate spacer or if there is
1)
adequate clearance to the metal.
Transponder flush-mounted in metal; minimum distance to the reader is 5 mm
2)
Transponder flush-mounted in metal; minimum distance to the reader is 10 mm
3)
Transponder flush-mounted in metal; minimum distance to the reader is 15 mm
4)
SIMATIC RF300
System Manual, 07/2017, C79000-G8976-C345-07
Reduction of field data due to metal, range as %: Transponder and RF340R
Without metal
On metal; distance 20 mm
Flush-mounted in metal;
distance all round 20 mm
Without metal
1)
On metal; distance 0 mm
Flush-mounted in metal;
distance all round 10 mm
Without metal
On metal; distance 0 mm
Flush-mounted in metal;
distance all round 20 mm
Without metal
On metal; distance 0 mm
Flush-mounted in metal;
distance all round 20 mm
Without metal
On metal; distance 20 mm
Flush-mounted in metal;
distance all round 20 mm
Without metal
On metal; distance 0 mm
Flush-mounted in metal;
distance all round 20 mm
Without metal
On metal; distance 0 mm
Flush-mounted in metal;
distance all round 40 mm
Without metal
100
85
75
3)
100
90
65
3)
100
65
60
3)
100
75
55
3)
100
75
70
3)
100
95
70
4)
100
100
80
4)
Planning the RF300 system
4.3 Installation guidelines
RF340R reader
On metal
Flush-mounted
in metal
(20 mm all-
round)
95
90
85
80
75
65
95
90
90
80
65
60
95
80
65
55
60
55
90
85
70
70
55
45
95
80
70
65
60
50
95
80
90
75
65
65
95
75
95
70
75
60
75