RF350R reader / ANT 30
Table 4- 12
RF320T
RF340T
RF350T
RF380R reader
Table 4- 13
RF320T
RF340T
RF350T
RF360T
RF370T
RF380T
All values are in mm
Values in brackets [ ] refer to RF380R with the MLFB 6GT2801-3AB10
The RF380R with MLFB 6GT2801-3AB10 enables the user to set the transmission output
power with the aid of the "distance_limiting" input parameter. For this, values from approx.
0.5 W to approx. 2.0 W can be set in 0.25 W increments. Depending on the setting, the
change to the transmission output power increases the performance in the lower operating
distance (low performance) or in the upper limit distance (high performance).
The "dili" value range goes from
02 (= 0.5 W) and
05 (default value: 1.25 W) to
08 (= 2 W).
Note
A dili value setting outside of the value range of 02 to 08 leads to the default setting (05) and
does not generate an error message.
Also see Chapter Minimum clearances (Page 47) Section "Minimum distance from reader to
reader".
You can find exact information regarding the parameters in the Product Information "FB 45
and FC 45 input parameters for RF300 and ISO transponders"
(http://support.automation.siemens.com/WW/view/en/33315697).
SIMATIC RF300
System Manual, 11/2009 - Zwischenstand 17.09.2009, A5E01642529-04
RF350R reader / ANT 30
Diameter of the transmission
window (L
)
d
15
25
25
RF380R reader
Length of the transmission window
in the x-direction (L
) in the y-direction (L
x
100
115
120
120
135
155
4.2 Field data for transponders, readers and antennas
Operating distance (S
)
a
2...11
5...15
5...16
Operating distance
(S
)
a
)
y
40
2...30 [40]
50
20...70 [80]
60
35...70 [100]
70
40...120
65
35...85 [100]
75
25...85 [110]
RF300 system planning
Limit distance (S
)
g
15
20
22
Limit distance (S
g
47 [55]
90 [100]
105 [130]
140 [150]
125 [135]
125 [140]
)
43