In general, the following points should be considered when mounting RFID components:
● Direct mounting on metal is allowed only in the case of specially approved transponders.
● Flush-mounting of the components in metal reduces the field data; a test is
● When working inside the transmission window, it should be ensured that no metal rail (or
The impact of metal on the field data (S
The values in the table describe the reduction of the field data in % with reference to non-
metal (100% means no impact).
4.5.4.2

RF310R

RF300 mode
Table 4- 22
Transponder
RF320T
RF340T
RF350T
RF360T
66
recommended in critical applications.
similar part) intersects the transmission field.
The metal rail would affect the field data.
Reduction of field data by metal (in %): Transponder and RF310R
Without metal
On metal; distance 20 mm
Flush-mounted in metal; distance
all-round 20 mm
Without metal
On metal
Flush-mounted in metal;
distance all-round 20 mm
Without metal
On metal
Flush-mounted in metal;
distance all-round 20 mm
Without metal
On metal; distance 20 mm
Flush-mounted in metal;
distance all-round 20 mm
, S
, L, B) is shown in tabular format in this section.
g
a
Without metal
100
100
80
100
80
70
100
70
60
100
100
60
System Manual, 11/2009 - Zwischenstand 17.09.2009, A5E01642529-04
RF310R reader
On metal
Flush-mounted
In metal
(20 mm all
around)
95
80
80
70
70
60
95
80
80
80
70
70
95
85
65
65
60
60
95
85
95
75
60
60