Output signal path "IP MPTS"/"IP SPTS" ........20 Transmission protocol ..............21 Port number ................21 Quantity of data packets .............22 Forward error correction ..............22 Transmission channel ..............22 Output IP address ...............23 Input parameter ................23 Data rate of the video signal ............24 - 2 - CCE 210...
Page 3
Programme number (SID - Service ID) ..........27 Channel name ................27 ASI station filter ................28 Transport stream ID and ORGNET ID ..........30 NIT ....................30 Factory reset .................31 Saving settings ................31 6 Final procedures ..................32 6.1 Combination with other cassettes .............32 - 3 - CCE 210...
European Council from January 27, 2003 which addresses old electronic and electrical devices, such devices must be disposed of at a designated collection facility. At the end of its service life, please take your device to one of these public collection facilities for proper disposal. - 4 - CCE 210...
General information Packing contents 1 Cassette CCE 210 1 BNC cable 1 LAN cable (RJ45) 1 Brief assembly instructions 1 CD (assembly instructions) Meaning of the symbols used Important note —> General note • Performing works Technical data The devices meet the following EU directives: 73/23/EWG, 89/336/EWG The product fulfils the guidelines and standards for CE labelling.
Page 6
ASI output: ..............1 BNC socket, 75 Ω Connection strip (10-pin): .........for supply voltages and control circuit RS-232 socket: ............serial update interface Remote maintenance Remotely controllable (via CCRS 1000*): ..........yes Remote update (via BEflash*): .............. yes (* and a corresponding management unit) - 6 - CCE 210...
The bit rates are adjustable. A transport stream fed via the ASI input socket will be inserted into the transport streams of the encoded analogous signals. In this way it is possible to connect several CCE 210 in series. At the ASI output sockets (BNC) a transport stream is provided according to ISO/IEC 13818-1.
– Before installing or changing a cassette unplug the power cable from the mains power socket. • Remove the fastening screws of an unoccupied slot from the bracket of the head-end station. • Insert the cassette in this slot and push it into the housing. • Align the cassette and apply slight pressure to connect it to the connections of the board and the HF bus bar. • Fasten the cassette with the screws 0° - 8 - CCE 210...
19" cabinet. Tighten the nuts on the cable terminals until the teeth on the lock washer have penetrated the exterior coating and a good connection is made between the hous- ing and cable terminals. - 9 - CCE 210...
The operating software of the cassette can be updated via the 9-pin D-SUB socket "RS 232" using a PC or notebook and the software "BE-Flash". You can find the current operating software on the website "www.triax.com". Connecting the cassette • Connect the peripheral devices via cable terminals to the input sockets "Video"...
The key pad on the head-end station is used to scroll through the menus: scrolls forward through the menus. scrolls backward through the menus. select parameters in the menus selects sub-menus set values,. saves all entries. - 11 - CCE 210...
ASI RATE IP 1 MODE/PORT IP SPTS 108000 KBits 1234 /RTP Bx 2 ASI OPTION IP 1 PKTS/FEC 188 pos. cont. /204 1…7 /neg. / 10/09 AnnexB / - 12 - CCE 210 /burst … / 20/19 AnnexB IP 1 OUT-IP...
Page 13
INPUT AV 1 => /AV 2 BITRATE /Audio only/2…15/off 5 Mbps INPUT /S-Video Composite NORM /PAL N PAL BG 4.43 MHz ASPECT /16:9 SHARPNESS /sharp/soft normal TELETEXT /OFF AUDIO Stereo 256 kbps /Joint/Dual/Mono L - 13 - CCE 210 /256/320/384...
Page 14
Bx 2 TS/ONID 0x0001,0100 Bx 2 on / off on / off auf Werkseinstellung Bx 2 FACTORY Bx 2 FACTORY zurücksetzen und speichern ▶ reset to factory defaults Defaults => STORE => M and store - 14 - CCE 210...
0. 0. 0. 0*" appears in the corresponding menu. The star " * " in the display means that the data is provided by a DHCP server. Bx 2 IP-ADDR 192.168. 0.128 - 16 - CCE 210...
• Use the buttons to select the digit of the IP address displayed to be set and use to set the IP address wished. • Press the button. —> The "UDP port" – "UDP-PORT" submenu is activated. - 17 - CCE 210...
—> Output signal path "IP MPTS"/"IP SPTS" see page 20. Output signal path "ASI" In this setting the output transport stream is provided via the ASI output. For this please also note chapter 6.1 "Combination with other cassettes" (page 32). Bx 2 OUTPUT => - 18 - CCE 210...
("188" or "204" bits). • If the polarity of the data to be transmitted has to be changed, press the to select "pos." (positive – standard) and using the buttons set to "neg." (negative). • To change the type of transmission press the buttons to select "cont." - 19 - CCE 210...
Bx 2 OUTPUT Bx 2 OUTPUT IP MPTS => IP SPTS => • Press the button. —> The "Transmission protocol, Port number" – "MODE / PORT" sub- menu is activated. - 20 - CCE 210...
• Using the buttons set the port number wished. • Press the button. —> The "Quantity of data packets, Forward error correction, Transmis- PKTS / FEC sion channel" – " " submenu is activated. - 21 - CCE 210...
"20/19"). Setting the transmission channel • Press the button to select"Annex…". • Use the buttons to set the transmission channel wished ("AnnexA" / "AnnexB"). • Press the button. —> The "Output IP address" – "OUT-IP" submenu is activated. - 22 - CCE 210...
INPUT Bx 2 INPUT AV 1 => AV 2 => • Using the buttons select the corresponding input. • Press the button. —> The "Data rate of the video signal " – "BITRATE" submenu is acti- vated. - 23 - CCE 210...
(Y/C) via the Mini DIN socket in this menu. INPUT Composite • Use the buttons to set the desired type of video signal. • Press the button. —> The "TV standard" – "NORM" submenu is activated. - 24 - CCE 210...
In this menu the you set the sharpness wished - "normal", "sharp" or "soft". SHARPNESS normal • Use the buttons to set the sharpness wished. • Press the button. —> The "Teletext options" – "TELETEXT" submenu is activated. - 25 - CCE 210...
("192" … "384" kbit/sec). The higher the bit rate, the higher the quality of the transmitted audio signal. Bear in mind that when the bit rate is increased, the bandwidth of the output signal is also increased. • Press the button. —> The "Level of the audio signal" –"VOLUME" submenu is activated. - 26 - CCE 210...
Service ID wished ("1" … "255"). —> A "!" behind the Service ID indicates that this ID is already in use by the other input. Using several CCE 210 (cascading see page 7) don´t assign the same SID twice.
Meaning of the indicators in the example: "ASI" ASI station filter "TV" "Television" (type of service) " " The currently selected service is activated. "01/07" The 1st of 7 services is being displayed. "Das Erste" Name of the service - 28 - CCE 210...
Page 29
• Press the button. —> Return to the main menu "ASI station filter" • Press the button. —> The "Transport stream ID and ORGNET ID" – "TS/ONID" main menu is activated. - 29 - CCE 210...
—> The "NIT" main menu is activated. Is a NIT generated via the remote control software CCRS 1000 (from SW V39 on), the CCE 210 is included. In this menu the NIT can be switched on or off. Bx 2 • Use the buttons to switch off or on the NIT.
The display shows "STORE" —> Back to "Selecting the cassette" (page 15). —> By pressing the button, you will be returned to the main menu "Ethernet parameters" without saving the factory defaults (page 16). Saving settings • Press the button. —> Return to "Selecting the cassette" (page 15). —> The settings are saved. - 31 - CCE 210...
INROUTE and OUTROUTE: For example cassette CCS-2 1000: At INROUTE setting "A+ASI=1 B+ASI=2" OUTROUTE must be set to "1=>ASI ASI=>MA" or "2=>ASI ASI=>MB". at INROUTE setting "A+B+ASI=1 ASI=2" OUTROUTE must be set to "1=>ASI ASI=>MA". - 32 - CCE 210...
Page 33
TRIAX A/S • Bjørnkærvej 3 • DK-8783 Hornsyld Alterations reserved. Technical data E. & O.E. V3/23112011...