Chicago Pneumatic CPC 40 G Instruction Book page 76

Oil-injected rotary screw compressors
Table of Contents

Advertisement

-
Condition
-
Condition
Excessive oil consumption; oil
carry-over through discharge line
-
Condition
Excessive oil flow through air
inlet filter after stopping
compressor
-
Condition
Safety valve blows after loading
-
Condition
Compressor element outlet
temperature or delivery air
temperature above normal
74
Fault
Choked air filter element
Solenoid valve malfunctioning
Leak in control air flexibles
Inlet valve does not fully open
Oil separator clogged
Air leakage
Safety valve leaking
Compressor element out of order Consult your supplier
Fault
Oil level too high
Incorrect oil causing foam
Oil separator defective
Scavenge line clogged
Fault
Check valve leaking or oil stop
valve jammed
Fault
Inlet valve malfunctioning
Minimum pressure valve
malfunctioning
Safety valve out of order
Compressor element out of order Consult your supplier
Oil separator element clogged
Fault
Oil level too low
On air-cooled compressors,
insufficient cooling air or cooling
air temperature too high
On water-cooled compressors,
cooling water flow too low
Instruction book
Remedy
Replace filter element
Replace valve
Replace leaking flexibles
Have valve checked
Have element replaced
Have leaks repaired
Have valve replaced
Remedy
Check for overfilling. Release
pressure and drain oil to
correct level
Change to correct oil
Have element checked.
Replace if necessary.
Check and remedy
Remedy
Replace defective parts.
Replace air filter element
Remedy
Have valve checked
Have valve checked
Have valve replaced
Have element replaced
Remedy
Check and correct
Check for cooling air
restriction or improve
ventilation of the compressor
room. Avoid circulation of
cooling air. If installed, check
capacity of compressor room
fan
Increase flow
2920 7101 41