Placement of Q-Tee Wall

Installation distance in case of non-combustible back wall
and combustible side wall
If the stove is to be installed above a wooden floor, it must be covered with a non-com-
bustible material at a thickness and seize, which is in accordance with UK Building Regula-
tions.

Normal set-up - corner setting

A. Distance to furniture (min.)
Distance to flammable materials (min.):
B. in front (floor)
C. to the side (floor)
E. to the side (combustable side wall)
G. to the ceiling
16
Uninsulated flue
650 mm
300 mm
150 mm
275 mm
800 mm
RAIS - Manual for RAIS Q-Tee
Insulated flue
650 mm
300 mm
150 mm
225 mm
800 mm
E