Accelerator Card Not Detected - HP SimpliVity OmniCube CN-3400 Installation And Maintenance Manual

Simplivity omnicube cn-1400, cn-2400, cn-3400, and cn-5400 series
Table of Contents

Advertisement

LED 1 glows or flashes green or yellow.
LED 2 glows or flashes green or red.
Table 10: Accelerator card LED states
Server state
Power up
POST
State save
State restore
Upgrade
HostCtrl

Accelerator card not detected

If the server is unable to detect or communicate with an Accelerator card after you power on the server or
perform a server firmware upgrade, you see error conditions.
LED 1
LED 2
Off
Off
Off
on, 1 off)
Off
Off
(2 on, 2 off)
Flashing yellow
Steady yellow
Steady green
Steady yellow
Flashing yellow
Flashing green
Flashing yellow
Description
PCIe 12 V power is not present.
Off
Configuration Programmable Logic
Steady red
Device (CPLD) detected power failure
or CPLD is not configured.
Field Programmable Gate Array
Flashing red (1
(FPGA) configuration error detected
or configuration failed.
FPGA configuration is complete.
Steady green
Firmware is not responding to health
Flashing red
check.
Power-on self test (POST) is
Steady green
executing.
POST failed.
Steady red
Normal operation (passed POST).
Steady green
NVRAM state save is in progress.
Flashing green
NVRAM state restore is in progress.
Flashing green
Firmware upgrade is in progress.
Flashing green
Not in service. Contact Customer
Flashing red
Support for a replacement.
Accelerator card monitoring
49

Hide quick links:

Advertisement

Table of Contents
loading