1.1 NVM Reset

To reset the panel back to factory defaults, follow the procedure below.
1. Open the panel, and disconnect the mains power (by removing the fuse from the terminal block) and the
battery.
2. Locate the pins marked "NVM RESET", and short them together using a length of wire or a jumper.
3. Re-apply the mains power.
4. After the panel has finished its start-up sequence, remove the short on the NVM reset pins, and connect
the battery.
The panel is now reset to factory defaults.
If the above procedure does not reset the panel, then "Engineer Code & NVM Reset" has been enabled. Follow
the procedure described on page 22 (Icon) or page 32 (LCD) in order to reset the system