Maintenance

Fuel

Use clean fuel oil that is not contaminated with water
and debris. Replace fuel filter and drain tank every 100
hours of operation.
Use No.1 or No 2 Heating Oil (ASTM D306) only.
NEVER use gasoline in your burner fuel tank. Gasoline
is more combustible than fuel oil and could result in a
serious explosion. NEVER use crankcase or waste oil
in your burner. Fuel unit malfunction could result from
contamination.
Fuel Control System
This machine utilizes a fuel solenoid valve located on
the fuel pump to control the flow of fuel to the combus-
tion chamber. The solenoid, which is normally closed, is
activated by a flow switch when water flows through it.
When the operator releases the trigger on the spray
gun, the flow of water through the flow switch stops,
turning off the electrical current to the fuel solenoid.
The solenoid then closes, shutting off the supply of fuel
to the combustion chamber. Controlling the flow of fuel
in this way gives an instantaneous burn-or-no-burn situ-
ation, thereby eliminating high and low water tempera-
tures and the combustion smoke normally associated
with machines incorporating a spray gun. Periodic
inspection, to insure that the fuel solenoid valve
functions properly, is recommended. This can be done
by operating the machine and checking to see that the
burner is not firing when the spray gun is in the OFF
position.
Fuel Pressure Adjustment:
To control water temperature, adjust fuel pressure by
turning the regulating pressure adjusting screw
clockwise to increase, counterclockwise to decrease.
Do not exceed 200 psi. NOTE: When changing fuel
pump, a bypass plug must be installed in return port or
fuel pump will not prime.

Burner Nozzle

Keep the tip free of surface deposits by wiping it with a
clean, solvent saturated cloth, being careful not to plug
or enlarge the nozzle. For maximum efficiency, replace
the nozzle each season.
18
Karcher HDS 600-606 Operator's Manual 9.800-080.0-AC

Electrode Setting

Electrode
1/8" FOR
AC CONE
Periodically Check Wiring Connections. If Necessary
To Adjust Electrodes, Use Diagram.
Kärcher ClearFire Oil Burner
Burner Air Adjustment: The oil burner on this
machine is preset for operation at altitudes below 500
feet. If operated at higher altitudes, it may be necessary
to adjust the air band for a #1 or #2 smoke spot on the
Bacharach scale.
To adjust, start machine and turn burner ON. Loosen
two locking screws found on the air band and close air
band until black smoke appears from burner exhaust
vent. Note air band position. Next, slowly open the air
band until white smoke just starts to appear. Turn air
band halfway back to the previously noted position.
Tighten locking screws.
1/4" Above
Nozzle Center
Nozzle
3/16" FOR
DC CONE