Operation
Starting the engine for the first time
To start the engine using the START button
on the machine or on the engine:
4
Start/stop buttons
1 STOP button
2 START button
On the engine: press START button 2
on the engine.
Monitor the oil pressure gauge immedi-
ately after starting the engine.
46
If the vehicle is equipped with a flame-start
system* or grid heater*:
Wait until the flame-start system*/
grid heater* indicator lamp goes out.
Start the engine within 30 seconds us-
ing the START button on the machine
or engine.
!
Keep the engine running at idling speed
until an oil pressure reading is dis-
played (do not rev the engine). If no oil
pressure is displayed after approxi-
mately 10 seconds, switch off the en-
gine. Determine the cause
(
page 48).
If necessary, interrupt the starting pro-
cedure after a maximum of 20 seconds,
and then repeat after approximately
1 minute.
!
The charge current indicator lamp and
electronic system warning lamp must
go out after the engine has started. If
they remain lit, this indicates that there
is a malfunction; (
see page 48) and
(
page 49).