Putting the boiler into operation:

Capacity of 9, 12, 15, 20, 25, 30, 35, 40, 45, 49,9 kW
1. Plug the connector of the power supply flex into the 230 V/50 Hz socket. Test the socket with
another appliance. The main switch of the boiler must be in the „off" position.
2. Let the gas flow into the boiler by turning a manual valve. When starting operation after a
longer period of inactivity, it is necessary to deaerate the gas piping. Force the air out by gas
through the burner (EKO, PLQ, P).
3. Set the thermostat to the maximum operation temperature.
4. Light the burner following the instructions on the internal side of the door (see more details in
the instructions EKO, PLQ, P).
5. Turn the boiler's main switch on. The control light goes on and the main burner is ignited. Set
the thermostat back to the required temperature of the heating water.
6. To put the boiler out of operation for a short time, turn the main switch off and thereby, the
boiler remains in the stand-by mode, disconnected from power supply.
7. To put the boiler out of operation for a long time, turn the combined valve into the „off" posi-
tion (see instruction EKO, PLQ, P), close the manual gas valve and put the power supply flex out
of the socket 230 V/50 Hz.
8. If it comes to the power failure during the operation, the gas supply into the burner is inter-
rupted, while the burner still burns (EKO, PLQ, P). When the power is supplied again, the burners
burn automatically without need of intervention.
9. For PLQ and KLQ modifications, the excessive output can be reduced by switching a button on
the front board. The excessive output is reduced automatically by the E and EZ modifications.
10. All the repairs during the guarantee and post-guarantee period have to be done by an author-
ized service organization.