Installing The Cables For The Bathymetric System - Simrad ME70 Installation Manual

Scientific multibeam echo sounder with bathymetry
Hide thumbs Also See for ME70:
Table of Contents

Advertisement

Simrad ME70 Installation Manual

Installing the cables for the bathymetric system

The bathymetric system cables include those used to connect the Hydrographic Work
Station to the display, to AC mains power, and to the Hydrographic Processing Unit.
The Hydrographic Processing Unit is also connected to the ME70 Transceiver Unit, and
to the global positioning system (GPS). One high capacity Ethernet cable connects the
Hydrographic Work Station to the Hydrographic Processing Unit.
Procedure
1
Connect the power cables.
a
Connect the power cable from the display to the power outlet on the uninterruptible
power supply (UPS). (C41)
b
Connect the power cable from the Hydrographic Work Station to the power outlet
on the uninterruptible power supply (UPS). (C42)
c
Connect the power cable from the Hydrographic Processing Unit to the power
outlet on the uninterruptible power supply (UPS). (C43)
Standard commercial AC mains cables are used. Each cable is supplied with the
relevant unit. The typical cable length is between 1,5 and 2 meters. If this is too short
you must use an extension cable (not recommended), mount a new power outlet within
range, or make your own power cable with sufficient length.
Hydrographic Work Station rear connectors, page 173
Hydrographic Processing Unit connectors, page 175
AC power cable using IEC C13 inline socket, page 188
2
Connect the ground cables.
a
If applicable, connect the ground cable from the display to vessel ground.
b
Connect the ground cable from the Hydrographic Work Station to vessel ground.
(C44)
c
Connect the ground cable from the Hydrographic Processing Unit to vessel
ground. (C45)
These cables must be provided by the installation shipyard.
Hydrographic Work Station rear connectors, page 173
Hydrographic Processing Unit connectors, page 175
Ground cable, page 190
148