Installatioin Instructions - Sharp AF-05CML Service Manual

Table of Contents

Advertisement

ACCESSORIES
No.
Right closure assembly
1
Left closure assembly
2
3
Window sash foam seal
4
Window sash foam seal
(adhesive type)
Bottom gasket
5
Screws(L=1",25.4mm)
6
Screws(L=
7
8
Base pan angle
SUGGESTED TOOLS
1. Screw driver (medium size Phillips)
2. Tape measure or ruler
3. Knife or scissors
INSTALLATION
WARNING: Make sure the unit is turned off and unplugged before working.
1. Cut the window sash foam seal (adhesive type) to the
proper length and attach it to the underside of the
window sash.
Jamb
Window sash foam seal
(adhesive type)
2. Insert the right closure assembly and the left closure
assembly into the top angle and the bottom channels.
Secure the right and left closure to the cabinet with six
of the provided screws. (L= 13/32",10mm)
3. Open the window sash and place the air conditioner on
the sill.
Balance the unit on the sill and close the window
sash securely behind the top angle.
INSTALLATION INSTALLATIONS
Accessories
13
/
",10mm)
32
Sash
Sill
Closure assembly
Q'ty
1
2
1
1
1
3
1
7
4
6
6
2
7
6
WARNING:
At this step, make sure the unit is inclinedapproximately
1 cm (3/8") to the back. If the unit is not properly
inclined, the water collected in the bottom tray during
operation will not drain properly and may flow into the
room where the air conditioner is installed.
Sill
4. Insert the bottom gasket into the space between the
window sill and the bottom of the unit to seal outside
air.
If there is space between the bottom channel and
the sill, fill the gap with a thin board or other hard filler.
Bottom gasket
5
1
5
7
8
2
Unit
incline backwards about 1cm
(
/
")
3
8
AF-05CML