Download Print this page

Advertisement

Quick Links

ROOM AIR CONDITIONER
INSTALLATION AND OPERATION
MANUAL
This INSTALLATION AND OPERATION MANUAL explains the proper use of your new
Conditioner. Read these instructions carefully before installing or operating your air conditioner. The
INSTALLATION AND OPERATION MANUAL should be kept in a safe place for handy reference.
AF-A18CE
AF-A24CE
CONTENTS
OPERATION INSTRUCTIONS ............. E-6
MODES OF OPERATION ..................... E-7
PAGE
SHARP Air

Advertisement

loading

Summary of Contents for Sharp AF-A18CE

  • Page 1: Table Of Contents

    BEFORE CALLING FOR SERVlCE ..E-10 This INSTALLATION AND OPERATION MANUAL explains the proper use of your new SHARP Air Conditioner. Read these instructions carefully before installing or operating your air conditioner. The INSTALLATION AND OPERATION MANUAL should be kept in a safe place for handy reference.
  • Page 3: Part Names And Dimensions

    PART NAMES AND DIMENSIONS Front panel Grille Air filter (behind the grille) Up/Down air flow adjustment louvers Left/Right air flow adjustment louvers Cabinet Ventilation lever Control panel Stopper screws (on left and right) Power cord DIMENSIONS AF-A18CE, AF-A24CE MODEL A (mm) B (mm) C (mm) 729 (center 740)
  • Page 4: Power Cabling

    INSTALLATION INSTRUCTIONS LOCATION The appliance shall be installed in accordance with national wiring regulations. Improper connection may cause the power cord and electrical outlet to overheat or fire. Install the air conditioner to the opening dimensions shown below. Never install the unit where any of the air inlet is blocked. The air conditioner should be installed with a strong external support to minimize noise and vibration, and for the purpose of safe installation, repair, replacement and secure positioning.
  • Page 5 INSTALLATION INSTRUCTIONS INSTALLATION WARNING Turn off and disconnect the unit before working. Remove the front panel by pulling the front panel at the lower corners towards you about 3 cm (1" ). Next lift it up and pull it towards you. (Fig.1) Front panel Fig.1...
  • Page 6 INSTALLATION INSTRUCTIONS Attach the drain joint provided with your air conditioner accessory to the back of the chassis for convenience when outside drainage becomes necessary. (Fig.4) Drain joint Fig.4 When drainage is necessary If outside water drainage is necessary in Drain joint high humidity district, or if you do not prefer the splashing sound of the non-...
  • Page 7 INSTALLATION INSTRUCTIONS Slide the chassis back into the Angle cabinet. Secure the chassis to the cabinet using the screw and angle removed in Step 2. Push the angle into the gap between the chassis and the cabinet. Slide the angle to the right until the holes meet, and screw it on Chassis to the chassis.
  • Page 8: Operation Instructions

    OPERATION INSTRUCTIONS OPERATION INSTRUCTIONS PRECAUTIONS POWER CORD REPLACEMENT WARNING: For replacement, use only the manufacturer specified power cord. Replacemant should be conducted by a qualified technician or a serviceman. Consult your dealer for detailed information concerning replacement of the power cord. WAIT FOR 3 MINUTES BEFORE RESTARTING THE COOLING OPERATION Whenever you turn the air conditioner OFF, wait for at least three (3) minutes before restarting the unit.
  • Page 9: Modes Of Operation

    MODES OF OPERATION PART NAMES WAIT THREE MINUTES BEFORE RESTARTING COOLER COOL COOL HIGH COOL AUTO SWING THERMOSTAT SELECTOR Control panel Auto swing switch Thermostat knob Selector knob Ventilation lever SELECTOR KNOB Use to select the desired mode. Both the fan and cooling operation are off. This setting can be used to circulate air whenever cooling is not desirable.
  • Page 10 MODES OF OPERATION THERMOSTAT KNOB Use to adjust the desired room temperature setting. The air conditioner will automatically maintain the room temperature according to the THERMOSTAT setting. The higher the numbers, the cooler the room temperature becomes. Experiments may be needed in order to find out the most suitable setting. AUTO SWING SWITCH Use to activate automatic louver movement during LOW COOL, MED COOL and HIGH COOL.
  • Page 11: Cleaning And Maintenance

    CLEANING AND MAINTENANCE WARNING : Turn off the unit before performing any cleaning or maintenance. CLEANING THE FILTER If the filter is clogged with dust, the amount of air flow will be reduced, resulting in poor cooling performance. The filter should be cleaned for every 10 days. At the beginning of every cooling season or if the air conditioner has not been used for a long period, clean the filter before starting to operate the unit.
  • Page 12: Before Calling For Servlce

    BEFORE CALLING FOR SERVlCE IF YOUR AIR CONDITIONER DOES NOT OPERATE PROPERLY, PLEASE CHECK THE FOLLOWING ITEMS BEFORE CALLING FOR SERVICE. AIR CONDITIONER DOES NOT OPERATE AT ALL • Is the power cord loosened or disconnected? • Is the fuse blown or has the circuit breaker been tripped? •...
  • Page 13 SHARP ELECTRONICS CORPORATION SHARP CORPORATION Osaka, Japan Printed in Thailand...

This manual is also suitable for: