Heating Of The Sauna Using The Steamer; Filling The Water Reservoir; Draining The Water Reservoir; Combi Heaters With An Automatic Water Filling System (Hl(S)7U1Sa, Hl(S)9U1Sa,Hl(S)11U1Sa, Hl(S)7U3Sa, Hl(S)9U3Sa, Hl(S)11U3Sa) - Harvia HL7U1SA Owner's/Operator's Manual

Table of Contents

Advertisement

Available languages

Available languages

Water property
Humus concentration
Iron concentration
Hardness: most important substances are
manganese (Mn) and lime, i.e. calcium (Ca)
Chlorinated water
Seawater
Table 1.
Water quality requirements

1.3. Heating of the Sauna Using the Steamer

With the Combi heater, the sauna can be heated
either in the usual way or by using its evaporator.
Always fill the water reservoir before use!
The evaporator has a 1,3 gal (5 l) water tank
so it can be on continuously for approximately
2 hours. The tank should be filled when the
heater is cold.

1.3.1. Filling the Water Reservoir

Fill the reservoir with clean household water always
before use. The maximum capacity of the reservoir
is approximately 1,3 gal (5 litres). Figure 2.
Switch the device off before adding the water to
the hot steamer.
Be careful, because the hot steam may
cause burns.
Filling the water reservoir
max.
min.

Draining the water reservoir

1
Figure 2.
Filling and draining the water reservoir
Effect
Colour, taste, precipitates
Colour, odour, taste, precipitates
Precipitates
Health risk
Rapid corrosion
5 l
2
EN
1.3.2. Draining the Water Reservoir
Drain the water from the reservoir always after use
when the water has cooled down. This procedure
removes impurities condensed in the reservoir as
result of evaporation.
1.3.3. Combi Heaters with an Automatic
Water Filling System
HL(S)9U1SA,HL(S)11U1SA, HL(S)7U3SA,
HL(S)9U3SA, HL(S)11U3SA)
Combi heaters that have an automatic water filling
system fill the tank automatically if the evaporator
is in the ON-position.

1.4. The Use of Fragrances

Liquid fragrances and fragrance bags can be used
in the steamer. Liquid fragrances are poured into
the stone cups in the steamer. Fragrance bags are
Always fill the water reservoir before use!
Recommendation
<12 mg/l
<0,2 mg/l
Mn: <0,05 mg/l
Ca: <100 mg/l
Forbidden to use
Forbidden to use
(HL(S)7U1SA,
Caution Very
hot Water!
5