Binary input/output modules
For pulse counting, for example kWh metering, the BIM with enhanced pulse counting capabilities must be used.
Note: 1BIM and 1 BOM required in slots P3 and P4.
Slot position (front/rear view)
1/2 Case with 1 TRM
3/4 Case with 2 TRM
1/1 Case with 2 TRM
Compression terminals
No board in slot
Binary output module 24
output relays (BOM)
BIM 16 inputs, RL24,
24-30VDC, 50mA
BIM 16 inputs, RL48,
48-60VDC, 50mA
BIM 16 inputs, RL110,
110-125VDC, 50mA
BIM 16 inputs, RL220,
220-250VDC, 50mA
BIM 16 inputs, RL220,
220-250VDC, 120mA
BIM 16 inputs, RL24,
24-30VDC, 50mA, enhanced
pulse counting
BIM 16 inputs, RL48,
48-60VDC, 50mA, enhanced
pulse counting
BIM 16 inputs, RL110,
110-125VDC, 50mA,
enhanced pulse counting
BIM 16 inputs, RL220,
220-250VDC, 50mA,
enhanced pulse counting
IOM 8 inputs, 10+2 outputs,
RL24, 24-30VDC, 50mA
IOM 8 inputs, 10+2 outputs,
RL48, 48-60VDC, 50mA
IOM 8 inputs, 10+2 outputs,
RL110, 110-125VDC, 50mA
IOM 8 inputs, 10+2 outputs,
RL220, 220-250VDC, 50mA
IOM8 inputs 10+2 outputs,
RL220, 220-250VDC, 110mA
IOM with MOV 8 inputs, 10+2
outputs, RL24, 24-30VDC,
50mA
IOM with MOV 8 inputs, 10+2
outputs, RL48, 48-60VDC,
50mA
IOM with MOV 8 inputs, 10+2
outputs, RL110, 110-125VDC,
50mA
IOM with MOV 8 inputs, 10+2
outputs, RL220, 220-250VDC,
50mA
mA input module MIM 6
channels
SOM Static binary output, 12
outputs; 6 standard relays + 6
static outputs, 48-60VDC
SOM Static binary output, 12
outputs; 6 standard relays + 6
static outputs, 110-250VDC
ABB
Ordering no
1MRK002960-KA
C
1MRK000614-AB
A
1MRK000508-DD
B1
1MRK000508-AD
C1
1MRK000508-BD
D1
1MRK000508-CD
E1
1MRK000508-CE
E2
1MRK000508-HA
1MRK000508-EA
1MRK000508-FA
1MRK000508-GA
1MRK000173-GD
1MRK000173-AE
1MRK000173-BE
1MRK000173-CE
1MRK000173-CF
1MRK000173-GC
1MRK000173-AD
1MRK000173-BD
1MRK000173-CD
1MRK000284-AB
1MRK002614-BA
1MRK002614-CA
Selection for
C
position #10
#10
X
X
X
X
X
X
A
A
A
A
A
A
B1
B1
B1
B1
B1
B1
C1
C1
C1
C1
C1
C1
D1
D1
D1
D1
D1
D1
E1
E1
E1
E1
E1
E1
E2
E2
E2
E2
E2
E2
F
F
F
F
F
F
G
G
G
G
G
G
H
H
H
H
H
H
K
K
K
K
K
K
L1
L1
L1
L1
L1
L1
M1
M1
M1
M1
M1
M1
N1
N1
N1
N1
N1
N1
P1
P1
P1
P1
P1
P1
P2
P2
P2
P2
P2
P2
U
U
U
U
U
U
V
V
V
V
V
V
W
W
W
W
W
W
Y
Y
Y
Y
Y
Y
R
R
R
R
R
R
T1
T1
T1
T1
T1
T1
T2
T2
T2
T2
T2
T2
1MRK 502 074-BEN A
Notes and rules
These black marks indicate the
maximum number of modules per
casing type and the slots that can
be occupied.
Only for A20
Only for B30/C30
Only for B30/C30
X
X
X
A
A
A
Maximum 4 (BOM+SOM+MIM)
boards.
B1
B1
B1
C1
C1
C1
D1
D1
D1
E1
E1
E1
E2
E2
E2
F
F
F
G
G
G
H
H
H
K
K
K
L1
L1
L1
M1
M1
M1
N1
N1
N1
P1
P1
P1
P2
P2
P2
U
U
U
V
V
V
W
W
W
Y
Y
Y
R
R
R
MIM not in A20, Maximum 1 MIM
board in 1/2 case.
T1
T1
SOM must not be placed in the
following positions: 1/2 case slot
P5, 3/4 case 2 TRM slot P7, 1/1
case 2 TRM slot P13.
T2
T2
137