Ordering For Pre-Configured Ied - ABB REG670 Product Manual

Relion 670 series, generator protection
Hide thumbs Also See for REG670:
Table of Contents

Advertisement

Generator protection REG670 2.2 and Injection equipment REX060,
REX061, REX062
Product version: 2.2.1

25. Ordering for pre-configured IED

Guidelines
Carefully read and follow the set of rules to ensure problem-free order management.
Please refer to the available functions table for included application functions.
PCM600 can be used to make changes and/or additions to the delivered factory configuration of the pre-configured.
To obtain the complete ordering code, please combine code from the tables, as given in the example below.
Example code: REG670 *2.2-A20X00- A02H39-B1X0-AA-CA-B-A12X0-CB1AL1XXXXXXXX-KKKXXHKKLAGXSY. Using the code of each position #1-11 specified as
REG670*1-2 2-3 3-4 4-5 6-7 7-8-9 9 9-10 10 10 10-11 11 11 11 11 11 11 11 11 11 11
#
1
- 2
REG670*
2.2
-
10
SOFTWARE
Version number
Version no.
Configuration alternatives
Generator differential and back-up
Generator differential and generator/transformer back-up
Generator/transformer differential and back-up
ACT configuration
ABB standard configuration
Software options
No option
Restricted earth fault protection, low impedance
High impedance differential protection - 3 blocks
Transformer differential protection - 2 winding
Transformer differential protection - 2 and 3 winding
Out-of-step protection
Rotor Fault Detection by Injection
Stator Fault Detection by Injection
Sensitive directional residual overcurrent and power protection
Voltage restrained overcurrent protection
Rotor overload protection
Four step directional negative phase sequence overcurrent protection - 1 block
Four step directional negative phase sequence overcurrent protection - 2 blocks
100% Stator E/F 3rd harmonic
Frequency time accumulation protection
Fuse failure supervision based on voltage difference
Control functionality for up to 30 objects
Transformer insulation loss of life monitoring
IEC 62439-3 Parallel redundancy protocol
IEC 62439-3 High-availability seamless redundancy
IEC 61850-9-2 Process Bus communication, 8 merging units
Synchrophasor report, 16 phasors
134
GUID-44AC94A2-C927-463B-BB10-F4C476745D03 v11
- 3
-
- 4
-
- 11
-
Selection for position #1
Ordering no
1MRK004007-AG
1MRK004007-BG
1MRK004007-CG
Selection for
position #2
Ordering no
1MRK004001-AA
1MRK004001-AB
1MRK004001-AP
1MRK004001-AR
1MRK004001-BW
1MRK004001-BV
1MRK004001-BX
1MRK004001-CT
1MRK004001-UN
1MRK004001-UR
1MRK004001-UH
1MRK004001-UK
1MRK004001-DE
1MRK004001-EC
1MRK004001-HC
1MRK004001-GZ
1MRK004001-KM
1MRK004001-PP
1MRK004001-PR
1MRK004001-PT
1MRK004001-PX
Selection for
position #3
1MRK 502 074-BEN A
- 5
6
- 7
- 8
- 9
-
-
-
-
Position
#1
Notes and rules
2.2
#2
Notes and rules
A20
B30
C30
X00
#3
Notes and rules
X00
All fields in the ordering form do
not need to be filled in.
A01
A01 only for B30
A02
A02 only for A20
A31
A31 only for A20
A33
A33 only for B30
B22
B31
B32
C16
C36
C38
C41
C41 only for A20
C42
C42 only for B30/C30
D21
D21 only for A20
E03
G03
H39
M21
M21 only for B30/C30
P23
Options P23 and P24 require two
SFPs placed in pairs.
P24
P30
P34
-
-
ABB