ABB REG670 Product Manual page 125

Relion 670 series, generator protection
Hide thumbs Also See for REG670:
Table of Contents

Advertisement

Generator protection REG670 2.2 and Injection equipment REX060,
REX061, REX062
Product version: 2.2.1
Table 188. Differential functions
Function
Transformer differential protection, two winding
Transformer differential protection, three winding
High impedance differential protection, single phase
Generator differential protection
Restricted earth fault protection, low impedance
Table 189. Impedance protection
Position
1
2
3
4
B
0
0
0
0
Table 190. Impedance functions
Note: Only 1 alternative may be selected
Function
Alternative 3 Distance protection, mho (mho for phase - phase fault and mho in parallel with quad for earth fault)
Full-scheme distance protection, mho characteristic
Directional impedance element for mho characteristic
Alternative 5 High speed distance protection, quadrilateral and mho
High speed distance protection, quad and mho characteristic
Alternative 6 High speed distance protection for series compensated lines, quadrilateral and mho
High speed distance protection for series comp. lines, quad and
mho characteristic
Optional with any alternative
Poleslip/out-of-step protection
Out-of-step protection
Loss of excitation
Sensitive rotor earth fault protection, injection based
100% stator earth fault protection, injection based
Underimpedance protection for generators and transformers
Table 191. Current protection
Position
1
2
3
C
00
Table 192. Current functions
Function
Instantaneous phase overcurrent protection
Directional phase overcurrent protection, four steps
Instantaneous residual overcurrent protection
Directional residual overcurrent protection, four steps
Four step directional negative phase sequence overcurrent
protection
Sensitive directional residual overcurrent and power protection
Thermal overload protection, two time constants
Breaker failure protection
Pole discordance protection
Directional underpower protection
Directional overpower protection
Negative sequence time overcurrent protection for machines
Accidental energizing protection for synchronous generator
Voltage restrained overcurrent protection
Stator overload protection
Rotor overload protection
ABB
5
6
7
8
9
10
0
0
0
0
4
5
6
7
8
0
Function
Ordering no
identification
T2WPDIF
1MRK005904-FC
T3WPDIF
1MRK005904-GB
HZPDIF
1MRK005904-HB
GENPDIF
1MRK005904-Kb
REFPDIF
1MRK005904-LC
11
12
13
14
15
16
0
0
0
0
Function
Ordering no
identification
ZMHPDIS
1MRK005907-FA
ZDMRDIR
1MRK005907-HA
ZMFPDIS
1MRK005907-SD
ZMFCPDIS
1MRK005907-RD
PSPPPAM
1MRK005908-CB
OOSPPAM
1MRK005908-GA
LEXPDIS
1MRK005908-BB
ROTIPHIZ
1MRK005908-EB
STTIPHIZ
1MRK005908-FB
ZGVPDIS
1MRK005907-TC
9
10
11
12
13
0
00
0
Function
Ordering no
identification
PHPIOC
1MRK005910-AD
OC4PTOC
1MRK005910-BC
EFPIOC
1MRK005910-DD
EF4PTOC
1MRK005910-EE
NS4PTOC
1MRK005910-FB
SDEPSDE
1MRK005910-GA
TRPTTR
1MRK005910-HC
CCRBRF
1MRK005910-LA
CCPDSC
1MRK005910-PA
GUPPDUP
1MRK005910-RA
GOPPDOP
1MRK005910-TA
NS2PTOC
1MRK005910-VA
AEGPVOC
1MRK005910-WA
VRPVOC
1MRK005910-XA
GSPTTR
1MRK005910-ZB
GRPTTR
1MRK005910-YB
Position
Available
Selected
qty
qty
4
0-2
5
0-2
6
0-6
7
0-2
8
0-3
17
18
19
20
21
0
0
0
0
Position
Available
Selected
qty
qty
6
0-4
8
0-2
14
0-1
15
0-1
21
0-1
22
0-1
23
0-2
24
0-1
25
0-1
26
0-2
14
15
16
17
18
19
0
0
Position
Available
Selected
qty
qty
1
0-4
2
0-6
4
0-2
5
0-6
6
0-2
7
0-2
10
0-3
11
0-4
14
0-4
15
0-4
16
0-4
19
0-2
20
0-2
21
0-3
22
0-1
23
0-1
1MRK 502 074-BEN A
Notes and rules
22
23
24
25
26
Notes and rules
20
21
22
23
Notes and rules
125