Ordering For Pre-Configured Ied - ABB Relion 670 REG670 Product Manual

Generator protection 2.1 iec
Hide thumbs Also See for Relion 670 REG670:
Table of Contents

Advertisement

Generator protection REG670 2.1 IEC
Product version: 2.1

22. Ordering for pre-configured IED

Guidelines
Carefully read and follow the set of rules to ensure problem-free order management.
Please refer to the available functions table for included application functions.
PCM600 can be used to make changes and/or additions to the delivered factory configuration of the pre-configured.
To obtain the complete ordering code, please combine code from the tables, as given in the example below.
Example code: REG670 *2.1-A30X00- A02H02-B1A3-AC-MB-B-A3X0-DAB1RGN1N1XXXXXXX-AXFXXX-AX. Using the code of each position #1-13 specified as
REG670*1-2 2-3 3 3 3 3 3 3 3 3 3 3 3 3-4 4-5-6-7 8-9-10 10 1010-11 11 11 11 11 11 11 11 11 11 11-12 12 12 12 12 12-13 13
#
1
- 2
REG670*
-
10
- 11
-
SOFTWARE
Version number
Version no
Configuration alternatives
Generator differential and back-up
Generator differential and generator/transformer back-up
Generator/transformer differential and back-up
ACT configuration
ABB standard configuration
Software options
No option
Restricted earth fault protection, low impedance
High impedance differential protection - 3 blocks
Transformer differential protection, 2 winding
Transformer differential protection, 2 and 3 winding
Out-of-step protection
Rotor Fault Detection by Injection
Stator Fault Detection by Injection
Sensitive directional residual overcurrent and power
protection
Voltage restrained overcurrent protection
Rotor overload protection
Four step directional negative phase sequence
overcurrent protection - 1 block
Four step directional negative phase sequence
overcurrent protection - 2 blocks
100% Stator E/F 3rd harmonic
Frequency time accumulation protection
Fuse failure supervision based on voltage difference
Apparatus control 30 objects
Circuit breaker condition monitoring - 6 CB
Circuit breaker condition monitoring - 12 CB
IEC 62439-3 parallel redundancy protocol
Selection for position #3
122
GUID-44AC94A2-C927-463B-BB10-F4C476745D03 v8.1.1
- 3
-
X00
A01
A02
A31
A33
- 4
-
- 12
.
Selection for position #1.
Selection for position #2.
#3
B22
B31
B32
C16
C36
C38
C41
C42
D21
E03
G03
1MRK 502 068-BEN D
- 5
6
- 7
-
-
#1
Notes and Rules
2.1
#2
Notes and Rules
A20
B30
C30
X00
Notes and Rules
All fields in the ordering form do
not need to be filled in
Note: A01 only for B30
Note: A02 only for A20
Note: A31 only for A20
Note: A33 only for B30
Note: C41 only for A20
Note: C42 only for B30/C30
Note: D21 only for A20
H09
M15
Note: M12 only for B30 and C30,
M15 only for A20
M12
P03
Note: P03 requires a 2-channel
OEM.
8
- 9
-
-
-
- 13
-
ABB