Mitsubishi MELSEC-F FX2N-1RM-E-SET User Manual page 96

Programmable cam switch
Table of Contents

Advertisement

FX
-1RM-E-SET Programmable Cam Switch
2N
Angle advance quantity (degrees) of S0 [FNC14]
< Key operation >
FNC
1
ON
OFF
1
0
GO
Rotation speed (rpm) of S1 [FNC15]
< Key operation >
FNC
1
ON
OFF
2
GO
Manipulate FNC16 to FNC26 in the same way as FNC13 to FNC15.
The operating procedures for the FNC16 to the FNC26 are omitted here.
4
GO
Set the angle advance quantity
·
(180 degrees maximum).
A decimal point indicates 0.5
degree.
5
GO
Set the rotation speed
0
(400 r/min maximum).
Program Operating Procedures 8
< Display >
BANK
OUT
STEP
0
d
EG
*1
*1 It indicates that S0 is being set.
*2 The existing value is displayed.
BANK
OUT
STEP
d
EG
0
When setting is finished, the contents of the
next FNC No. (FNC15) are displayed.
*3 " · " (decimal point) indicates 0.5 degree.
< Display >
BANK
OUT
STEP
1
S
Pd
*1
*1 It indicates that S1 is being set.
*2 The existing value is displayed.
BANK
OUT
STEP
S
Pd
1
When setting is finished, the contents of the
next FNC No. are displayed.
DEG
"0" is
displayed
*2
DEG
"10 ·"
flashes*3
DEG
"0" is
displayed
*2
DEG
"20"
flashes*3
8-16