Current angle transfer function

The current angle transfer function to transfers the current angle of the resolver to BFM#106 via
turning ON input terminal B1.
(This function has been included since V2.40)
The PLC is used together, and a highly accurate sampling by which an external input is made a
trigger can be done.
The response speed becomes 207r/min/0.5degree or 415r/min/degree.
Set to specify the bank from the PLC without fail when you use the current angle transfer
function.
< Setting by the data setting panel >
Set the method of specifying the bank by operating FNC3, "PLC".
Refer to Paragraph 8.3.4
Set the current angle transfer function by operating FNC7, "Effective".
Refer to Paragraph 8.3.8
< Setting by the PLC >
BFM#0 b3 is turned ON, and the method of specifying the bank selects "PLC".
BFM#0 b7 is turned ON, and the Current Angle Transfer function is made effective.
b7: OFF → Current angle transfer function is Invalidity.
ON → Current angle transfer function is effective.
Program example
M8000
M8000
M8000
M8000
M8000
M8000
M8000
M8000
M8002
BFM#106
Reading instruction
Resolution: 1 degree
M0
Rotation derection of resolver: Clockwise
M1
Write protect of EEPROM: Write is enabled
M2
Bank specification method: PLC
M3
Automatic angle advance function: Un used
M4
Individual automatic angle advance function:
M5
Un used
Prohibition of RUN to PRG operation:
M6
Permission
Current angle transfer function: Used
M7
TO
K0
K1
FROM
K0
K106
K2M0
K1
Parameter setting (BFM#0)
BFM#106 → D0.
D0
K1
Basic Setting 6
6-11