Write-Protect Function Of The Eeprom [Fnc2]; Bank Specification Method [Fnc3] - Mitsubishi MELSEC-F FX2N-1RM-E-SET User Manual

Programmable cam switch
Table of Contents

Advertisement

FX
-1RM-E-SET Programmable Cam Switch
2N
8.3.3

Write-protect function of the EEPROM [FNC2]

Enable or prohibit write of data to the EEPROM built in the FX
< Key operation >
FNC
2
ON
OFF
GO
8.3.4

Bank specification method [FNC3]

Select the program bank specification method.
< Key operation >
FNC
3
ON
OFF
GO
GO
GO
Program Operating Procedures 8
[Power ON] [PRG mode]
-1RM.
2N
< Display >
BANK
OUT
STEP
0
0
0
*1 Initial value (write enabled).
BANK
OUT
STEP
0
0
0
When setting is finished, the contents of the
next FNC No. (FNC3) are displayed.
While the OFF LED is lit: Write enabled
While the ON LED is lit: Write prohibited
[Power ON] [PRG mode]
< Display >
BANK
OUT
STEP
0
0
0
*1 Initial value (specifies by an external
input of FX
-1RM).
2N
BANK
OUT
STEP
0
0
0
When setting is finished, the contents of the
next FNC No. (FNC4) are displayed.
While the OFF LED is lit:Specifies by an external input of
FX
While the ON LED is lit :Specificat ion from programmable
controller
Set to specify the bank from the PLC without
fail when you use the current angle transfer
function.
DEG
ON LED
OFF LED
Exting-
F02
Lit*1
uished
DEG
ON LED
OFF LED
Exting-
F 02
Flashes
uished
DEG
ON LED
OFF LED
Exting-
F03
Lit *1
uished
DEG
ON LED
OFF LED
Exting-
F03
Flashes
uished
-1RM
2N
8-14