Applicable Markings; Certifications; Explosive (Hazardous) Environment; Safety - FLIR GFx320 User Manual

Gfx3xx series
Table of Contents

Advertisement

2
Safety information
6. Equipment Protection Level (EPL): EPL is linked to the intended use and zones. Gc
is linked to Gas Group II, Zone 2 and constitutes minimum protection level of either n,
ic or pz.
7. Equipment Group: Group I = Mines, Group II = Other.
8. Equipment Category: 3 = Equipment suitable for use in Zone 2.
9. G = Gas.

2.2.6 Applicable markings

2.2.7 Certifications

• ATEX/IECEx, Ex ic nC op is IIC T4 Gc
II 3 G
• ANSI/ISA-12.12.01-2013, Class I Division 2
• CSA 22.2 No. 213, Class I Division 2

2.2.8 Explosive (hazardous) environment

Standards related to explosive (hazardous) environment that the camera complies with:
• IEC 60079-0:2011
• IEC 60079-11:2011
• IEC 60079-15:2010 (partial)
• IEC 60079-28:2015
• BS EN 60079-0:2012
• BS EN 60079-11:2012
• BS EN 60079-15:2010
• BS EN 60079-28:2015
• ANSI/ISA-12.12.01-2013
• CSA 22.2 No. 213
• ATEX directive 2014/34/EU

2.2.9 Safety

Standards related to safety that the camera complies with:
• EN/UL/IEC 60950-1
#T810169; r. AN/42241/42268; en-US
10

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents