Terms In This Manual - Brymen BM089 User Manual

Clamp-on multimeter
Table of Contents

Advertisement

1) SAFETY
This manual contains information and warnings that must be followed
for operating the instrument safely and maintaining the instrument in
a safe operating condition. If the instrument is used in a manner not
specified by the manufacturer, the protection provided by the
instrument may be impaired.
The meter protection rating, against the users, is double insulation
per UL/IEC/EN61010-1 Ed. 3.0, IEC/EN61010-2-033 Ed. 1.0, CAN/CSA
C22.2 No. 61010-1 Ed. 3.0, IEC/EN61010-2-032 Ed.
IEC/EN61010-031 Ed. 1.1:
Measurement Category III 1000V & Category IV 600V AC & DC.
Per IEC61010-1 (2010) OVERVOLTAGE CATEGORY
OVERVOLTAGE CATEGORY ll (CAT II) is for equipment intended to
be supplied from the building wiring. It applies both to plug-
connected
EQUIPMENT.
OVERVOLTAGE CATEGORY lll (CAT III) is for equipment intended
to form part of a building wiring installation. Such equipment includes
socket outlets, fuse panels, and some MAINS installation control
equipment.
OVERVOLTAGE CATEGORY lV (CAT IV) is for equipment installed
at or near the origin of the electrical supply to a building, between
the building entrance and the main distribution board. Such
equipment may include electricity tariff meters and primary
overcurrent protection devices.

TERMS IN THIS MANUAL

WARNING identifies conditions and actions that could result in
serious injury or even death to the user.
CAUTIONidentifies conditions and actions that could cause damage
or malfunction in the instrument.
equipment
and
to
PERMANENTLY
3
3.0
&
CONNECTED

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Bm088 dc+acBm083 acBm086Bm088Bm083

Table of Contents