Installing The Remote Controller; Installation; Setting The Dip Switch - Fujitsu UTY-RNN*M series Installation Manual

Air conditioner remote controller (wired type)
Table of Contents

Advertisement

5. INSTALLING THE REMOTE
CONTROLLER

5.1. Installation

5.1.1. INSTALLING THE REMOTE CONTROLLER

Open the operation panel on the front of the remote controller, remove the
2 screws indicated in the following fi gure, and then remove the front case of
the remote controller.
When installing the remote controller, remove the connector from the
front case.
The wires may break if the connector is not removed and the front case
hangs down.
When installing the front case, connect the connector to the front case.
Fig. 1
SET BACK
Screws
When remote controller cable is embedded
(1) Embed the remote controller cable and box.
(2) Pass the remote controller cable through the hole in the rear case and
connect the remote controller cable to the remote controller terminal
board specifi ed in Fig. 2.
(3) Clamp the remote controller cable sheath with the binder as shown in
Fig. 2.
(4) Cut off the excess binder.
(5) Install the rear case to the wall, box, etc., with 2 screws (Fig. 3).
Fig. 2
1. 12V
2. Signal
(Red)
(White)
1. 12V
(Red) 2. Signal
Hole
Binder
Fig. 3 [Example]
Box
Rear
case
En-3
Front case
Rear case
(back side)
Connector
3. COM
(Black)
7
7
7
Unit : mm
(White)
3. COM
(Black)
CAUTION
When connecting the remote
controller cables, do not over
tighten the screws.
Remote controller
cable
Connector
Screws
Earth (Ground) the remote controller if it has an earth (a ground) cable.
Wrap the connector and remote controller
cables with vinyl tape or some other type
of insulation as shown in the fi gure.
Remote controller

5.2. Setting the DIP switch

Install the remote controller wires so as not to be direct touched with
your hand.
• Do not touch the remote controller PC board and PC board parts
directly with your hands.
Set the remote controller DIP switches.
Set DIP switch 1 - NO.6 to ON.
For the other switch, set it according to the situation.
[Example]
Front case (back side)
Do not use this
DIP switch 2
Switch state
NO.
OFF
1
2
Follow the
selection in
3
9.FUNCTION
SETTING
DIP switch 1
4
5
6
Invalidity
CAUTION
OFF
1
2
3
4
5
6
DIP switch 1
Detail
ON
Cannot be used. (Do not
change)
Dual remote controller
setting
* Refer to 6.2. Dual
remote control in
6. INSTALLATION
METHODS.
Filter reset operation
Invalidity
and fi lter display
Cannot be used. (Do not
change)
Cannot be used. (Do not
change)
Memory backup setting
* Set to ON to use bat-
teries for the memory
backup. If batteries are
Validity
not used, all of the set-
tings stored in memory
will be deleted if there
is a power failure.
(
Factory setting)
ON