ELECTRICAL CONNECTION
To connect the supply cable:
•
Remove the screws securing the co-
ver 'A' on the rear of the cooker (fig.
8.1).
•
Fitted with a 5-pole terminal block,
position the U-bolts 'C' onto terminal
block 'B' (fig. 8.1) according to the dia-
gramS in fig. 8.2.
•
Feed the supply cable through the
cable clamp 'D' (fig. 8.1). The supply
cable must be of a suitable size for the
current requirements of the appliance;
see the section "Feeder cable section".
•
Connect the wires to the terminal block
'B' as shown in the diagrams in figure
8.2.
•
Take up any slack in the cable and se-
cure with the cable clamp 'D'.
•
Replace the cover 'A'.
Fig. 8.1
Before effecting any intervention on
the electrical parts of the appliance,
the connection to the network must be
interrupted.
FEEDER CABLE SECTION
"TYPE H05RR-F"
220 V ac
3 x 2,5 mm
220 V 3 ac
4 x 2,5 mm
380 V 3N ac
5 x 2,5 mm
380 V 2N ac
4 x 2,5 mm
(**) Connection with wall box connection.
–
Diversity factor applied.
–
A diversity factor may be applied to the
total loading of the appliance only by a
suitably qualified person.
220 V
1 2 3 4 5
L
N (L
)
PE
1
2
380 V 3N
1 2 3 4 5
L
L
L
N
PE
1
2
3
(**)
2
(**)
2
(**)
2
(**)
2
Fig. 8.2
220 V 3
1 2 3 4 5
L
L
L
PE
1
2
3
380 V 2N
1 2 3 4 5
L
L
N
PE
1
2
31