Victron energy Color Control GX Manual page 7

Hide thumbs Also See for Color Control GX:

Advertisement

Color Control GX manual [Victron Energy]
Item
AC input 2
Battery monitor
Synchronize VE.Bus SOC with battery
Has DC system
Display & language
Brightness
Display off time
Show mobile overview
Language
VRM online portal
Log to
Log interval
Wireless AC Sensors
Select the position for each AC sensor (PV Inverter on AC-input 1, 2 or on AC-output). More information about the Wireless AC sensors. (/live/ccgx:ccgx_wireless_ac_sensor)
Wired AC Sensors
Configure the Wired AC Sensor, used for one of three things:
measure the output of a PV Inverter,
measure and regulate a Hub-4 system (/live/system_integration:hub4_grid_parallel-ccgx_control_loop)
measure the output of an AC Generator.
Ethernet
Select the configuration type (DHCP vs. manual configuration) and IP settings.
Wi-Fi
Manage wireless networks and IP settings.
GPS
Format
Speed unit
Generator start/stop
Configure generator autostart settings and conditions. Generator auto start/stop with Color Control GX (/live/ccgx:generator_start_stop)
Tank pump
Configure automatic starting and stopping of pump based on tank level. Pump auto start/stop with Color Control GX (/live/ccgx:pump_start_stop)
Relay
Function
Polarity
Services
ModbusTCP
VRM two-way communication
When using a VE.Bus system, it is possible to configure the severity of problems on the VE.Bus system that should cause a notification to show up on the CCGX (and make it beep):
Disabled: the CCGX should never beep and show a notification
Alarm only: the CCGX should only beep and a show a notification when the VE.Bus system switched off in an alarm condition.
Enabled (default): the CCGX should beep and show a notification
When all done, don't forget to change the access level to user when required.
Click the thumbnail below to see the complete menu-tree:
(/live/_media/ccgx:menustructure_ccgx.jpeg)
2.2 Logging data for the VRM portal
7 de 13
Default
Description
Grid
Same choices as above.
Automatic
Select the SOC source. Useful for systems with multiple BMVs. More details (/live
/ccgx:start#select_soc_source_from_the_gui_to_display_on_the_main_overview_screen). If using the VRM portal, ensure the VRM Main
Battery source setting under Settings –> General on the VRM site matches the CCGX SOC source.
No
Continuously updates the VE.Bus SOC with the one provided by the selected battery monitor. Note: do not use this in combination with an
Hub-2 Assistant.
No
Enable this for boats, vehicles and other installations with DC loads and chargers other than the Multi and MPPT chargers. Not applicable for
most off-grid installations. The difference between the DC current measured by the Multi and by the BMV will be attributed to a 'DC system'.
It can be an alternator, pumps, DC fridge, etcetera. Note that the value shown will always be an approximation.(in order to achieve this and
make changes in the system setup page, you have to change the access level to user&installer, the initial password is "zzz")
Configure the brightness between 0 and 100%
Set between 10 seconds and 30 minutes, or never
No
Enable this to show the mobile overview page which is designed for Marine and RV applications. This overview gives direct access to the AC
Current limit as well as the On/Off/Charger only settings and pump control. Also shows up to four tank levels.
English
Choose between English, Dutch, Chinese, German, Spanish, French, Italian, Swedish, Turkish and Arabic.
Internet
Choose between no logging at all, logging via the internet directly to the VRM Portal, and logging to a microSD card or USB flash drive. See
chapter 2.2 below for more information.
15 minutes
Set to anything between 1 minute and 1 day. Choose longer times on systems with an unreliable connection. Note that this setting does not
affect reporting problems and state changes (bulk → absorption) to the VRM Portal: such events will initiate an immediate transmission of all
parameters.
Select the format in which to show the Latitude and Longitude.
km/h
Choose between km/h, meters per second, miles per hour or knots.
Alarm relay
Select the relay function. Possible functions are Alarm relay, Generator start/stop, Tank pump and None(disabled).
Normally open
Select the polarity of the relay on the back of the CCGX. Normally open or normally closed. Note that setting it to normally closed increases
the CCGX power draw.
Off
This setting enables the ModbusTCP service. More information about ModbusTCP in this document: https://www.victronenergy.com/upload
/documents/Whitepaper-Data-communication-with-Victron-Energy-products_EN.pdf
/Whitepaper-Data-communication-with-Victron-Energy-products_EN.pdf]
No
Enable remote configuration and firmware updates. CCGX Remote VEConfigure and firmware updates (/live/ccgx:ccgx_ve_power_setup)
https://www.victronenergy.com/live/ccgx:start