Connecting Sas Cables To The Server Or Controller Enclosure - HPE D3600 User Manual

D3000 series disk enclosure
Hide thumbs Also See for D3600:
Table of Contents

Advertisement

Connecting SAS cables to the server or controller enclosure

To connect the first disk enclosure to the server or controller enclosure, use a standard mini-SAS
cable.
IMPORTANT:
top I/O module (I/O module A) in the disk enclosure is supported for use.
Observe the following guidelines:
Only use supported SAS cables with mini-SAS connectors.
Ensure that the servers or controller enclosures are powered down and power cords are
disconnected before connecting SAS cables to the disk enclosure.
The following illustration demonstrates connecting a disk enclosure to a server with an installed
controller. In your environment, the disk enclosure might connect to a controller enclosure, which
then connects to the host or network. Regardless of environment, cabling principles from the
disk enclosure to the host are the same.
Note the following when connecting cables:
P1 on the disk enclosure I/O module is treated as the SAS "in" port.
P2 on the disk enclosure I/O module is treated as the SAS "out" port.
In single-domain configurations, one cable path is created between the host, the primary
disk enclosure, and additional cascaded disk enclosures. (Shown)
In dual-domain configurations, two cable paths are created between the host, the primary
disk enclosure, and additional cascaded disk enclosures.
When connecting this disk enclosure in a single-domain environment, only the
Connecting SAS cables and power cords
35

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

D3610D3700D3710

Table of Contents