Recommended Accessories - Hameg HM7042-5 User Manual

Triple power supply
Hide thumbs Also See for HM7042-5:
Table of Contents

Advertisement

Technical Data
Triple Power Supply
HM7042-5
All data valid at 23 °C after 30 minutes warm-up.
Outputs
2 x 0...32 V/2 A and
0..5,5 V/5 A
Output 1 + 3 (32 V)
Range:
Ripple:
Current:
Current limit/electronic fuse:
Recovery time (10...90 % load
variation):
Max. transient deviation:
Recovery time (50 % basic load,
10 % load variation):
Max. transient deviation:
Display:
7-Segment LED:
Resolution:
Display accuracy:
LED:
Output 2 (5,5 V)
Range:
Ripple:
Current:
Current limit/electronic fuse:
Recovery time (10...90 % load
variation):
Max. transient deviation:
Recovery time (50 % basic load,
10 % load variation):
Max. transient deviation:
Display:
7-Segment LED
Resolution:
Display accuracy:
LED
Maximum ratings
Max. voltage applicable to output terminals:
CH 1 + CH 3
CH 2
Reverse voltage:
Reverse current:
Voltage to earth:
北京海洋兴业科技股份有限公司(证券代码:839145)
ON/OFF pushbutton control, SMPS
followed by a linear regulator, floating
outputs for parallel/serial operation,
current limit and electronic fuse
2 x 0...32V, continuously adjustable 2
knobs (coarse / fine)
≤100µVEff (3Hz....300kHz) typ.,
≤1mV (10Hz...1MHz)
max. 2 A
0...2 A, continuously adjustable (knob)
80 µs within ±1 mV of nominal value
30 µs within ±10 mV of nominal value
0 µs within ±100 mV of nominal value
typ. 75 mV
30 µs within ±1 mV of nominal value
5 µs within ±10 mV of nominal value
0 µs within ±100 mV of nominal value
typ. 17 mV
32,00 V (4 Digit) / 2,000 A (4 Digit)
0,01 V/1 mA
±3 digit voltage / ±4 digit current
indicates current limit
0...5.5 V, continuously adjustable (knobs)
≤100µVEff (3Hz....300kHz) typ.,
≤1mV (10Hz...1MHz)
max. 5 A
0...5 A, continuously adjustable (knob)
80 µs within ±1 mV of nominal value
10 µs within ±100 mV of nominal value
typ. 170 mV
30 µs within ±1 mV of nominal value
15 µs within ±10 mV of nominal value
0 µs within ±100 mV of nominal valuee
typ. 60 mV
5,50 V (3 Digit) / 5,00 A (3 Digit)
0,01 V/10 mA
±3 digit voltage/±1 digit current
indicates current limit
33 V
6 V
max. 0,4 V
max. 5 A
max. 150 V
Miscellaneous
Safety class:
Mains supply:
Mains Fuse:
Power consumption:
Operating temperature:
Storage temperature:
Rel. humidity:
Dimensions (W x H x D):
Weight:
Accessories supplied:
Operating manual, line cord

Recommended accessories:

HZ10S 5 x silicone test lead (black)
HZ10R 5 x silicone test lead (red)
HZ10B 5 x silicone test lead (blue)
HZ42
19" Rackmount Kit 2RU
Te c h n i c a l D a t a
Safety class I (EN61010-1)
115 V/230 V ±10 %; 50...60 Hz, CAT II
115 V: 2 x 5 A; slow blow 5 x 20 mm
230 V: 2 x 2,5 A; slow blow 5 x 20 mm
max. 330 VA/250 W
+5...+40 °C
-20...+70 °C
5...80 % (non condensing)
285 x 75 x 365 mm