A.1.1
Bulk Oil Systems
Bulk oil systems have large oil storage
tanks, typically located in the rear of the
restaurant, that are connected to a rear
manifold on the fryer.
pumped from the fryer, via a fitting
located on the rear of the fryer labeled
DISPOSE (see Figure 1). , to the disposal
tanks and fresh oil is pumped from the
tanks, thru the fitting located on the rear of
the fryer labeled FILL, to the fryer (see
Figure 2).
Connect the bulk oil
connections to plug located on the rear of
the fryer (see Figure 3). The wiring
diagram is located on the next page.
It is imperative that the fryer system be
completely power cycled after changing
any fresh or waste oil settings.
The FilterQuick
fryers, equipped for use
with bulk oil systems, have an onboard
fresh oil jug supplied by the bulk oil
provider. Remove the cap and insert the
standard fitting into the jug with the metal
cap resting on the lip of the jug. The oil is
pumped in and out of the jug through the
same fitting. (see Figure 4).
Figure 4
* NOTE: It takes approximately twelve seconds from the time the fill JIB button is pressed until the
fresh bulk oil pump starts. It may take up to 20 seconds before the level in the JIB begins to
rise. Typically it takes approximately three minutes to fill the JIB. It takes approximately
one minute to fill a split vat and two minutes to fill a full vat.
Waste oil is
Waste Oil
Connection
Bulk wiring
connection
The momentary switch used to reset the ATO system is
also used to fill the jug in an fresh bulk oil system. After
clearing the TOP OFF EMPTY display, pressing and
holding the momentary switch, located above the JIB,
allows the operator to fill the jug from the bulk oil storage
tank (see Figure 5).
To fill the jug, press and hold the JIB reset button until the
jug is full, then release.*
NOTE: Do NOT overfill the
jug.
For instructions on filling the
vat from bulk, see the
FilterQuick Controller Manual
Section 1.9.8 page 1-16.
A–1
Figure 1
Figure 2
Do not add HOT or
USED oil to a JIB.
Figure 3
Fresh Oil
Connection
WARNING:
Figure 5

Hide quick links: