5.7.3 Clean Combustion Air Blower Assembly

1. Disconnect the blower wiring harness and remove the four blower mounting nuts.
(See Figure 1 on below)
Wiring connection
2. Remove the three fasteners that secure the blower motor assembly to the blower housing, and separate the two
components. (See Figure 2)
3. Wrap the motor with plastic wrap to prevent water from entering it. Spray degreaser or detergent on the
blower wheel and the blower housing. Allow it to soak for five minutes. Rinse the wheel and housing with
hot tap water, then dry with a clean cloth. (See Figure 3)
4. Remove the plastic wrap from the blower motor assembly. Reassemble the blower motor assembly and
blower housing. Reinstall the blower assembly in the fryer.
5. Reinstall the blower shield or shield assembly.
6. Light the fryer in accordance with the procedure described in Chapter 3, Section 3.2.2.
Blower
assembly
mounting nuts
Figure 1
Wrap the motor and wires
with plastic wrap or a
plastic bag.
Figure 3
5-6
Remove these fasteners.
Figure 2
Blower Housing
Blower Wheel