Vertex Standard EVX-539 Operating Manual

Vertex Standard EVX-539 Operating Manual

Hide thumbs Also See for EVX-539:

Advertisement

EVX-539
O
perating
1
A
2
3
4
B
5
6
7
C
8
9
?
D
0
#
EVX-539
p
M
 IP57 Submersible (1 m/30 min.)
anual
 9 Programmable Function Keys
 2-Tone Encode/Decode
 5-Tone Encode/Decode
 MDC-1200
 Scan
 Group Scan
 Dual Watch
 FM-Scan ( Follow-Me Scan )
 TA Scan
 Encryption
 Privacy
 VOX
 Talk Around
 Emergency
 Lone Worker
 TX Save Disable
 Direct Channel Entry
 Code Up/Down
 Code Set
 Speed Dial
 DTMF Code Set
 ID Check
 ARTS
F
rOgraMMable
unctiOns
Encode/Decode
®
ø 1
ø 2
ø 1
ø 1
ø 1
ø 1
ø 1
II
( Auto Range Transpond System )
ø 1
/ARTS
TM
TM
ø 1: Analog mode only
ø 2: Digital mode only
FCC ID: AXI11154620
IC: 10239A-11154620
/F
eatures
ø 1
ø 1
ø 1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the EVX-539 and is the answer not in the manual?

Questions and answers

Summary of Contents for Vertex Standard EVX-539

  • Page 1 FCC ID: AXI11154620 IC: 10239A-11154620 EVX-539 rOgraMMable unctiOns eatures  IP57 Submersible (1 m/30 min.) perating anual  9 Programmable Function Keys ø 1  2-Tone Encode/Decode ø 1  5-Tone Encode/Decode ø 1  MDC-1200 Encode/Decode ®  Scan  Group Scan ...
  • Page 2: Table Of Contents

    FCC ID: AXI11154620 IC: 10239A-11154620 Ontents Introduction...............1 Operation..............9 Warning!.FCC.RF.Exposure.Requirements...2 Preliminary Steps ..........9 Before.You.Begin............4 Operation Quick Start ..........9 Battery Pack Installation and Removal ....4 Automatic Time-Out Timer .......12 Battery Charging ..........4 Advanced.Operation..........13 Low Battery Indication ........5 Programmable Key Functions ......13 Belt Clip Installation and Removal .....6 Description of Operating Functions ....16 MIC/SP Cap Installation ........6 Lock................28 Controls.&.Connectors.
  • Page 3: Introduction

    VHF/UHF Land Mobile bands. This transceiver is designed for reliable business communications in a wide variety of applications with a wide range of operating capability provided by their leading-edge design. The EVX-539 allows to 512-channel capacity and 32 groups which can each be programmed with an 8-character Alpha-Numeric Tag.
  • Page 4: Warning!.Fcc.rf.exposure.requirements

     This radio is NOT approved for use by the general population in an uncontrolled exposure environment. This radio is restricted to occupational use, work related operations only where the radio operator must have the knowledge to control his or her RF exposure conditions. EVX-539 O pErating anual...
  • Page 5 NOT comply with the FCC RF exposure requirements and should be avoided.  When operate the radio with the Vertex Standard CLIP-20 belt-clip, make the transmission time as short as possible, to keep the Body Worn configuration.
  • Page 6: Before.you.begin

    1/2 inch (1.5 cm). Then lift the battery out from the radio. PA-55 Do not attempt to open any of the re- chargeable Lithium-Ion packs, as they could explode if accidentally short-circuited. CD-58 EVX-539 O pErating anual...
  • Page 7: Low Battery Indication

    Battery Pack. CAUTION 2) Use only the Vertex Standard CD-58 Desktop Charger and the Vertex Standard PA-55 AC Adapter. Danger of explosion if battery is replaced 3) To reduce the risk of explosion, recharge the bat- with an incorrect battery.
  • Page 8: Belt Clip Installation And Removal

     Use only the supplied screws when install the MIC/SP cap.  This radio does not keep the submersible Rating (IP57: 1 meter / 30 minutes) when the MIC/SP cap is not installed in the MIC/SP jack. EVX-539 O pErating anual...
  • Page 9 FCC ID: AXI11154620 IC: 10239A-11154620 EVX-539 O pErating anual...
  • Page 10: Controls.&.Connectors

    Steady Green: Tone Squelch in defeated condition TOP SEL ( Top Select ) Key LCD ( Liquid Crystal Display ) 16-Button DTMF Keypad PTT Switch MIC/SP Jack ( External MIC/SP ) SIDE-1 Button SIDE-2 Button EVX-539 Speaker Battery Pack Latch Microphone EVX-539 O pErating anual...
  • Page 11: Lcd.icons.&.Indicators

    Battery Indicator Low Transmit Power Mode “On” Priority-2 Channel Option SW (Key Function) Group Number is activated “Privacy” or “Encryption” is activated “Group Scan” is enabled RSSI Indicator (four steps) 8-character Alpha-numeric Display “VOX” is activated EVX-539 O pErating anual...
  • Page 12: Preliminary Steps

    LCD. til you are familiar with the basic operation of the The radio announces the EVX-539. Refer to page 11 for more information channel number, if the Channel Announcement about Speaker/Microphone usage. Feature is enabled via the clone editor software.
  • Page 13 Speak into the screws from the right microphone area of the side of the transceiver, front panel grille in a normal voice level. To re- then align the connector turn to the Receive mode, release the PTT switch. EVX-539 O pErating anual...
  • Page 14: Automatic Time-Out Timer

     If the BTLO (Busy Tone Lockout) feature has been programmed on an analog channel or CCLO (Color Code Lockout) feature has been programmed on a digital channel, the radio EVX-539 O pErating anual...
  • Page 15: Advanced.operation

    In this chapter, the following icons are used to indi- cate features supported in either the “Analog” mode The EVX-539 provides the nine programmable func- or “Digital” mode: tion ( PF ) keys: TOP SEL, SIDE-1, SIDE-2, [ A ] , [ B ] , [ C ] , [ D ], [ Ý...
  • Page 16 --- / --- / --- / --- / --- / RPI-2 Set PRI-2 Disable PRI-2 Direct CH 1 Direct CH 2 Direct CH 3 Direct CH 4 Direct CH Entry Scan Group Scan Dual Watch FM-Scan EVX-539 O pErating anual...
  • Page 17 Call 2 Call 3 Call 4 Call 5 Code Up Code Down Code Set Speed Dial DTMF Code Set Call Status Set Status Up Status Down Status Check Duty ID Check ARTS Login TX Save Disable Lock EVX-539 O pErating anual...
  • Page 18: Description Of Operating Functions

    “Normal” transmit power more information of the “User Set (Menu)” mode. when in difficult terrain. When the radio’s transmitter is set to “Low Power” mode, the “L” icon will be indicated on the display. EVX-539 O pErating anual...
  • Page 19 (lower) level pro- tone will sound, and the current squelch level will grammed by your Vertex Standard dealer. appear on the display.  Press the SIDE-1/SIDE-2 buttons (or [ A ] / [ B ]...
  • Page 20 “VOX O.N” briefly, and activates mErgEncY the VOX function; allowing hands-free, automatic The EVX-539 includes an “Emergency” feature in activation of the transmitter, based on voice input into either analog or digital modes, which may be useful the microphone. When the VOX function is activated, for alerting another party monitoring on the same fre- a small dot (“.”) will be indicated at the bottom right...
  • Page 21 Press, (or press and hold), the assigned PF key to re- lect a different group of channels. A group name will call the pre-programmed PRI-2 (Priority-2) Channel appear briefly on the display. by your Vertex Standard dealer directly. cH u cH 1 cH 4...
  • Page 22  The channel which defined in the CH Selector ning, the transceiver will check each channel for the knob. presence of a signal, and will stop on a channel if a signal is present. EVX-539 can scan both digital and analog frequency programmed channels simultane- ously. EVX-539 O...
  • Page 23 To stop Dual Watch: will revert to the programmed revert channel.  Press, (or press and hold), the assigned PF key. The “DW” icon disappear from the display.  Operation will revert to the “Dual Watch Revert” channel. EVX-539 O pErating anual...
  • Page 24 To include the current Group in the scanning loop, press, (or press and hold), the assigned PF key (the “  ” icon will appear on the display). To remove a current Group from Group Scan, press, (or press and EVX-539 O pErating anual...
  • Page 25 Note that your dealer may have mode provision for quency every few seconds (interval programmed by “Talk Around” channels by programming “repeater” your Vertex Standard dealer). and “Talk Around” frequencies on two adjacent chan- nels. If so, the key may be used for one of the other Note: The TA Scan feature does not activate on the Pre-Programmed Functions.
  • Page 26 Press, (or press and hold), the assigned PF key to corresponding to the Auto-Dial memory number list select a 2-Tone or 5-Tone encode code from the pre- provided by your Vertex Standard dealer or Network programmed encode list. Administrator. The DTMF tones sent during the dial- ing sequence will be heard in the speaker.
  • Page 27 Press, (or press and hold), the assigned PF key to check the 5-tone receive status code. When you press this key, the display will indicate the “Message” cor- responding to the receive status condition per the pre- defined status list. EVX-539 O pErating anual...
  • Page 28  Press the [ C ] key to send the Call back, when recalling the ID of the “5-tone Signaling”, if de- sired. You may cancel the Call back sending by press- ing the [ C ] key. In this case, the display indicates “- CANCEL -” briefly. EVX-539 O pErating anual...
  • Page 29 The precise lockout configuration is pro- Under some circumstances, though, your hand-held grammed by your Vertex Standard Dealer. radio may not be heard well at the other end of the communication path, and high power may be neces- sary at all times.
  • Page 30: Lock

    YstEm The ARTS system is enhanced feature of the ARTS which can be finding out the communication range of the radio individually by using the MDC- 1200 Encode/Decoder. ® EVX-539 O pErating anual...
  • Page 31: User.set.mode

    FCC ID: AXI11154620 IC: 10239A-11154620 The EVX-539 includes a “User Set” (Menu) Mode which allows the user to define or configure various settings, such as Squelch, Display contrast, etc. To activate the “User Set” (Menu) Mode:  Press the [ D ] key to store the new configuration.
  • Page 32: Optional.accessories

    MH-66 Submersible Speaker Microphone others may be unavailable in some regions. Check Over-the-head VOX Compatible Headset MH-81 with your Vertex Standard Dealer for changes to ATV-16A VHF Antenna (136-150 MHz) this list. VHF Antenna (150-162 MHz) ATV-16B...
  • Page 33 FCC ID: AXI11154620 IC: 10239A-11154620 EVX-539 O pErating anual...
  • Page 34: Warranty.policy

    IC: 10239A-11154620 arrantY olIcY Vertex Standard warrants, to the original purchaser only, its Vertex Standard manufactured communications prod- ucts against defects in materials and workmanship under normal use and service for a given period of time from the date of purchase.
  • Page 35 FCC ID: AXI11154620 IC: 10239A-11154620 The AMBE+2TM voice coding Technology embodied in this product is protected by intellectual property rights including patent rights, copyrights and trade secrets of Digital Voice Systems, Inc. This voice coding Technology is licensed solely for use within this Communications Equipment. The user of this Technology is explicitly prohibited from attempting to decompile, reverse engineer, or disassemble the Object Code, or in any other way convert the Object Code into a human-readable form. U.S. Pat. Nos. #5,870,405, #5,826,222, #5,754,974, #5,701,390, #5,715,365, #5,649,050, #5,630,011, #5,581,656, #5,517,511, #5,491,772, #5,247,579, #5,226,084 and #5,195,166. Part 15.21: Changes or modifications to this device not expressly approved by Vertex Standard could void the user’s authorization to operate this device.
  • Page 36 FCC ID: AXI11154620 IC: 10239A-11154620 Vertex Standard LMR, Inc. Copyright 2013 Vertex Standard LMR, Inc. All rights reserved. No portion of this manual may be reproduced without the permission of Vertex Standard LMR, Inc.

Table of Contents