Waste Gate Actuator Leak Test; Installation Of Turbocharger - Yanmar 3TNV82A-B Service Manual

Industrial
Hide thumbs Also See for 3TNV82A-B:
Table of Contents

Advertisement

Periodic Inspection
1. Connect a hand-operated air pump to the waste
gate actuator pipe (Figure 10-6, (1)). The pump
should be equipped with a 30 psi (0.21 MPa;
2
2.21 kgf/cm
) pressure gauge
(Figure 10-6, (2)), and a pressure release valve
to release any pressure pumped into the
system. (Similar pumps are used to check for
leaks in marine gear cases.)
A
WARNING
Never apply over 40 psi (2.8 kgf/cm) to
the waste gate actuator.
(3)
Figure 10-6
2. Apply 17 psi (0.12 MPa; 1.2 kgf/cm
waste gate actuator (Figure 10-6, (3)) circuit.
Observe if the waste gate valve is open fully. If
the waste valve does not open fully, replace the
turbocharger or have it repaired by a qualified
repair facility.

Waste Gate Actuator Leak Test

Allow the pressure, 17 psi (0.12 MPa; 1.2 kgf/cm
to remain in the circuit for one minute. After one
minute, observe the pressure reading.
TNV DI Service Manual
• If the pressure reading is equal to or greater
• If the pressure reading is less than 15.9 psi

Installation of Turbocharger

1. Pour 2 oz (60 cc) of clean engine oil in the oil
inlet port at the top of the turbocharger. Rotate
the compressor wheel to ensure the shaft
0000026en
bearings are lubricated.
2. Flush the oil lines to ensure that they are free of
containments.
3. Put a new turbocharger exhaust manifold
gasket in place and reinstall turbocharger on
the exhaust manifold.
(1
4. Apply anti-seize compound to the turbocharger
mounting studs.
(2)
5. Reinstall the mounting nuts. Torque the nuts to
the specified torque.
6. Install new sealing washers and O-rings and
reinstall the inlet and outlet oil lines to the
turbocharger.
00001617
Do not allow any material to fall into the
oil lines or the oil inlet and outlet ports
2
) to the
of the turbocharger.
7. Reinstall the air inlet connection to the
turbocharger turbine housing.
8. Reinstall the exhaust connection to the
turbocharger compressor housing.
2
)
TURBOCHARGER
than 15.9 psi (0.11 MPa; 1.1 kgf/cm
waste gate actuator is not leaking and is
operating properly.
2
(0.11 MPa; 1.1 kgf/cm
actuator is leaking. Replace the turbocharger
or have it repaired by a qualified repair facility.
CAUTION
2
), the
), the waste gate
0000064en
10-15

Advertisement

Table of Contents
loading

Table of Contents