3. S
ETUP

AC Power

The Intimidator Beam 355 IRC has an auto-ranging power supply and it can work with an input voltage
range of 100 to 240 VAC, 50/60 Hz. To determine the product's power requirements (circuit breaker, power
outlet, and wiring), use the current value listed on the label affixed to the product's back panel, or refer to
the product's specifications chart. The listed current rating indicates the product's average current draw
under normal conditions.
Always connect the product to a protected circuit (a circuit breaker or fuse). Make
sure the product has an appropriate electrical ground to avoid the risk of
electrocution or fire.
To eliminate unnecessary wear and improve its lifespan, during periods of non-use
completely disconnect the product from power via breaker or by unplugging it.
Never connect the product to a rheostat (variable resistor) or dimmer circuit, even
if the rheostat or dimmer channel serves only as a 0 to 100% switch.

Fuse Replacement

1.
Disconnect the product from power.
2.
Using a flat-head screwdriver, unscrew the fuse holder cap from the housing.
3.
Remove the blown fuse.
4.
Replace with a fuse of the same type and rating.
5.
Screw the fuse holder cap back in place and reconnect power.
Disconnect the product from the power outlet before replacing the fuse.

Power Linking

The product provides power linking via the Edison outlet located in the back of the product. Please see the
diagram below for further explanation.
Power Linking Diagram
Power
Source
nd
2
Product
rd
3
Product
You can power link up to 5 Intimidator Beam 355 IRC products on 120 VAC or up
to 9 Intimidator Beam 355 IRC products on 230 VAC.
Page 4 of 20