Adjusting the light barriers
Fig. 14: Adjusting the right switching flag
(1) - Screw
Fig. 15: Adjusting the left switching flag
(1) - Screw
Adjusting steps
1. Loosen the screw (1).
2. Adjust the switching flag (2) accordingly.
3. Set the zero point via the control unit.
4. Tighten the screw (1).
5. Reference the machine.
4.3 Thread clamp switching flag
The thread clamp switching flag is used as reference by the control unit for
the thread clamp. The switching flag is located underneath the throat plate
to the right and is factory set.
Service Instructions 512-211-01/532-211-01 - 01.0 - 10/2017
①
②
①
②
(2) - Switching flag, right
(2) - Switching flag, left
23