EM 241 Modem Module Specifications

Table A-42
EM 241 Modem Module Order Number
Order Number
6ES7 241–1AA22–0XA0
EM 241 Modem Module
1 Eight Q outputs are used as logical controls of the modem function and do not directly control any external signals.
Table A-43
EM 241 Modem Module General Specifications
Order Number
Module Name and Description
6ES7 241–1AA22–0XA0
EM 241 Modem Module
Table A-44
EM 241 Modem Module Specifications
General
Telephone Connection
Isolation
(phone line to logic and field power)
Physical connection
Modem standards
Security features
Dialing
Messaging Protocols
Industrial Protocols
24 VDC Input Power Requirements
Voltage range
Isolation (field power to logic)
The EM 241 Modem Module replaces the function of an
external modem connected to the communications port
of the CPU. With an EM 241 installed in your S7-200
system, all you need to communicate with your CPU
from a remote location is a personal computer with an
external modem and STEP 7–Micro/WIN.
See Chapter 7, Communicating over a Network, for
information on configuring. See Chapter 10, Creating a
Program for the Modem Module for programming and
advanced features of the module.
Expansion Model
Dimensions (mm)
(W x H x D)
71.2 x 80 x 62
1500 VAC (Galvanic)
RJ11 (6 position, 4 wire)
Bell 103, Bell 212, V.21, V.22, V.22 bis, V.23c, V.32, V.32 bis,
V.34 (default)
Password
Callback
Pulse or Tone
Numeric
TAP (alphanumeric)
UCP commands 1, 30, 51
Modbus
PPI
20.4 to 28.8 VDC
500 VAC for 1 minute
Country Code Switch
Figure A-26
Technical Specifications Appendix A
EM Inputs
EM Outputs
1
8
VDC Requirements
Weight
Dissipation
+5 VDC
190 g
2.1 W
80 mA
6ES7 241–1AA22–0XA0
EM 241 Modem Module Terminal Block
Diagram
Removable
Connector
No
+24 VDC
70 mA
A
385