1551E or 1553 Selected for Scanner Model
When "1551E" or "1553" is selected from the Scanner model option (see
step 4 above), and the port state is already enabled (see step 5), the process
will take several moments to reset. When 1551E or 1553 is successfully
connected during this step, the unit will emit some beeps. Here, the termi-
nal is initializing the scanner at 9600 for the baud rate, 7 data bits, even
parity, and 2 stop bits and synchronizing the terminal's configuration with
the attached scanner.
With "1551E" or "1553" selected, Symbologies, Symbology Options,
Hardware Trigger, and Scanner Port settings are configured from the In-
termec Settings applet. See the the Intermec Computer Command Reference
Manual, available from the Intermec web site at www.intermec.com, for
more information about each enabled option.
ASCII Selected for Scanner Model
To send data coming into the 700 Series Computer through the COM1
port from an external input device, as keyboard data to an application on
the desktop, do the following:
1 Select "ASCII" from the Scanner model option.
2 Tap to check Scanner Port State.
3 Tap File > Save Settings from the bottom of the screen.
With "ASCII" selected, Symbology Options, Hardware Trigger, and Scan-
ner Port settings are configured from the Intermec Settings applet. See the
the Intermec Computer Command Reference Manual, available from the In-
termec web site at www.intermec.com, for more information about each
enabled option.