Serial Communication details
The Serial Communication screen details are explained as follows:
Option
Description
Serial
Selects serial communication devices (Serial Device 1 and Serial Device 2) in BIOS. BIOS console redirection can
Communication
also be enabled, and the port address can be specified. This option is set to Auto by default.
Enables the COM port or Console Redirection options. This option is set to Off by default.
Serial Port Address Enables you to set the port address for serial devices. This option is set to Serial Device1=COM2, Serial Device
2=COM1 by default.
External Serial
Enables you to associate the External Serial Connector to Serial Device 1, Serial Device 2, or the Remote Access
Connector
Device by using this option. This option is set to Serial Device 1 by default.
Failsafe Baud Rate
Specifies the failsafe baud rate for console redirection. The BIOS attempts to determine the baud rate
automatically. This failsafe baud rate is used only if the attempt fails, and the value must not be changed. This
option is set to 115200 by default.
Remote Terminal
Sets the remote console terminal type. This option is set to VT100/VT220 by default.
Type
Redirection After
Enables or disables the BIOS console redirection when the operating system is loaded. This option is set to
Boot
Enabled by default.
System Profile Settings
You can use the System Profile Settings screen to enable specific system performance settings such as power management.
Viewing System Profile Settings
To view the System Profile Settings screen, perform the following steps:
1
Turn on, or restart your system.
2
Press F2 immediately after you see the following message:
F2 = System Setup
NOTE:
If your operating system begins to load before you press F2, wait for the system to finish booting, and then
restart your system and try again.
118
Pre-operating system management applications
NOTE:
You can use only Serial Device 2 for the Serial Over LAN (SOL) feature. To use console
redirection by SOL, configure the same port address for console redirection and the serial device.
NOTE:
Every time the system boots, the BIOS syncs the serial MUX setting saved in iDRAC. The serial
MUX setting can independently be changed in iDRAC. Loading the BIOS default settings from within
the BIOS setup utility may not always revert the serial MUX setting to the default setting of Serial
Device 1.
NOTE:
Only Serial Device 2 can be used for Serial Over LAN (SOL). To use console redirection by SOL,
configure the same port address for console redirection and the serial device.
NOTE:
Every time the system boots, the BIOS syncs the serial MUX setting saved in iDRAC. The serial
MUX setting can independently be changed in iDRAC. Loading the BIOS default settings from within
the BIOS setup utility may not always revert this setting to the default setting of Serial Device 1.