  • Page 1 PAY-TO-PARK 11 9 G F 8 8E N CONTROL SYSTEM INSTALLATION MANUAL PS ONE English...
  • Page 2: Table Of Contents

    SUMMARY System diagram ............................Description ..............................Technical specifications ..........................Wiring diagram ............................Dimensions (mm) ............................Example of system layout with side-by-side entrance and exit lanes .............10 Entrance unit / exit unit card and connections - description ..............12 Automatic pay station card - description ....................14 Automatic pay station card - installation ....................18 10.
  • Page 3: System Diagram

    OCR video camera The PS ONE is designed for the use with devices with "native" Ethernet interface. This system management offers the opportunity to configure numerous peripherals such as automatic pay stations, entry and exit units, entrances for permit holders, pedestrian readers and manned pay stations.
  • Page 4: Description

    Description Central server This is the core of the system. The server hosts the software for access control and monitoring (even remotely) and VoIP control unit management software for the integrated phone system. Automatic pay station Unit for automatic payment that involves the following main functions: - Reading and printing of tickets - TAG RFID proximity card reading - TFT 15.4 ’...
  • Page 5: Technical Specifications

    Technical specifications The specified characteristics are indicative. They may be changed without prior notice. Central server Power supply 230 V - 50 Hz - 150 W Container Micro tower Microprocessor Dual Core 1.5 GHz AMD Turion II PC3-10600E DDR 2GB RAID - 2 x 500GB SATA drivers Embedded NC107i PCI Express Gigabit Ethernet Network control...
  • Page 6 Manned pay station Power supply External 12 V / 24 V - 270 W (with supplied adapter) Container Integrated system with ABS plastic adjustable monitor Display 15 ' TFT LCD panel, 1024x768 w/ resistive touch screen Microprocessor Intel E5300 Pentium Dual Core, 2.60 GHz DDR2 512 MB 500 GB Dimensions...
  • Page 7: Wiring Diagram

    4 Wiring diagram For grid connections strictly follow the IEEE standard ISO / OSI 802.3 or IEEE 802.11 ATM reader Receipt printer Intercom station Central server Manned pay station GSM router. Desktop printer Automatic pay station ETHERNET Barcode ticket reader Long Range I / O Interface RFID Reader...
  • Page 8: Dimensions (Mm)

    5 Overall dimensions (mm) Please note that the units must be fixed on a base 120 at a minimum depth of 600. Entrance unit - Exit unit PSICD01 PSOCD01 PSI1S PSO1S Anchor base Front Base and foundation slab...
  • Page 9 Automatic pay station The automatic pay station must be installed in a sheltered area protected from rain, snow, dust, or other elements. If necessary, install elements such as canopies and side panels to protect the pay station against atmospheric and environmental agents.
  • Page 10: Example Of System Layout With Side-By-Side Entrance And Exit Lanes

    Example of system layout with side-by-side entrance and exit lanes Note: the example shows the minimum dimensions (in mm) between the components of the system. These measures are to be met for correct operation. EXIT ENTRY Description of the components OCR video camera Entrance unit Vehicle detection loop...
  • Page 11 Entrance unit / exit unit card and connections - description Traffic light fuse F1=1A-T 12. Input status indicator LED Traffic light connection terminal 13. Input connection terminals Fan and heater connection terminal 14. Printer power supply terminal Barrier connection terminal 15.
  • Page 12: Entrance Unit / Exit Unit Card And Connections - Description

    Entrance - exit unit LED index input INPUT CONDITION OF LED ON: N.B. Vehicle presence detection of loop 1 Vehicle on Safety loop located under the barrier Vehicle presence detection of loop 2 optional Vehicle Classifier Axle Detection Activation optional Vehicle Classification Photocell Free optional Barrier open...
  • Page 13 Entrance - exit unit "Connections Board" Ticket key 10. Microphone 11. Extraction fan LCD Backlight 12. Reserved User keys 13. Reserved Ticket slit LED 14. Accessory power supply Rfid Reader 15. Jumper closed Brightness sensor 16. LH LED strip Power supply and data input 17.
  • Page 14: Automatic Pay Station Card - Description

    8 Automatic pay station card - description 10. Input status indicator LED VAC power supply input 11. Operating LED Interior lighting connection terminal 12. Input connection terminals Fan and heater connection terminal 13. Vdc power supply inputs Remote alarm output terminal 14.
  • Page 15 LED index input on automatic pay station card INPUT CONDITION OF LED ON: N.B. Upper door closed (maintenance compartment) Middle door closed (cash compartment) Collection Drawer Fitted Coins Drawer Fitted Coins Drawer Engaged Vac power present Automatic Pay Station CPU connections USB camera USB audio interface connection...
  • Page 16 Compact Flash Memory Slot Receipt Printer RS232 connection CCTALK interface RS232 connection CCTALK card STATUS DESCRIPTION Green LED RUN (fl ashing ON) Red LED ERROR (normally OFF) Blue LED CCTALK RX line (normally OFF) Yellow CCTALK CHx line (normally OFF) LEDs: Activation key for card self-diagnostics TEST 11.
  • Page 17 Automatic Pay Station Connections Board Coin slot shutter 10. Microphone 11. Coin slit LED LCD Backlight 12. Reserved User keys 13. Reserved Ticket slit LED 14. Accessories power supply Rfid Reader 15. Jumper open Brightness sensor 16. Reserved Power supply and data input 17.
  • Page 18: Automatic Pay Station Card - Installation

    9 Automatic pay station - installation Wear protective gloves when installing the system. 9.1 Automatic pay station installation Top element The automatic pay station is supplied in three elements that require assembly: • base plate • central element • top element Central element Base - Apply three steel cables with hooks at the end with a capacity...
  • Page 19 - Position the top element above the central one, and then secure the nine screws supplied. - Remove the screw that secures the printer. -Connect the LED connector to the top element on the left side of the pay station.
  • Page 20 Connect the ground cable to the top element. 9.2 Power supply and ETHERNET connection Power from the main electrical panel of the site to provide adequate all-pole disconnect device for disconnecting line voltage (MCB + RCD). Required characteristics: • Circuit breaker with breaking current up to 16 A (230 V) or 25 A (120 V); •...
  • Page 21 - Plug the power cables in the correct locations of the socket. - Fix the shell on the socket by tightening the respective fixing screws. - Inside the upper compartment on the left side, connect the power cord from the base to its terminal. - Inside the top compartment on the left side, connect the Ethernet cable to its terminal.
  • Page 22 9.3 Installing the UPS (not supplied) The uninterruptible power supply (UPS) must be suited to the characteristics of the electricity grid and to the environmental characteristics related to the installation site. UPS REQUIRED CHARACTERISTICS Output power 500 W / 750 VA Type of wave Sine wave Output connection type...
  • Page 23 9.5 Status LED Status LED A LED indicator that indicates the status by colour is located on the top section of the automatic pay station: LED COLOUR DESCRIPTION Blue Automatic pay station active Automatic pay station not working / undergoing maintenance Green Operation successful 9.6 Automatic Pay Station power supply wiring diagram...
  • Page 24: Entrance Unit / Exit Unit - Installation

    Entrance unit / exit unit - installation Wear protective gloves when installing the system. 10.1 Preparing the entrance and exit unit The following illustrations are only examples, given that the space for securing the entrance and exit units and accessories varies depending on the overall dimensions. The installation technician is responsible for choosing the most suitable solution.
  • Page 25: Entrance Unit / Exit Unit - Electrical Connections

    - In the exit station, remove the screws that hold - In the entry station, remove the screw that    the ticket reader and the container secures the Roboticket printer or base printer    Entrance unit / exit unit - electrical connections Wear protective gloves when installing the system.
  • Page 26 11.2 Barrier connection - Access to the control board of the unit by removing the cover of the container. - Identify the connection to the barriers on the control board (see entrance - exit unit board) and then make connections. NB: For installation and programming see the manual included in the packaging of the barrier installed.
  • Page 27 11.3 Vehicle crossing loops connection - Locate the SMA detector installed in the barrier, then connect the vehicle crossing loop. - On the unit control board, locate the terminal to connect the SMA detector installed in the barrier, and then make connections.
  • Page 28 - Position the cover and secure it. 11.5 Power supply Power from the main electrical panel of the site to provide adequate all-pole disconnect device for disconnecting line voltage (MCB + RCD). Required characteristics: • Circuit breaker with breaking current up to 16 A (230 V) or 25 A (120 V); •...
  • Page 29 - Plug the power cables in the correct locations of the socket. - Fix the shell on the socket by tightening the respective fixing screws. - Locate the power supply terminal and make the connection.
  • Page 30 11.6 ETHERNET connection - Inside the bottom section of the unit connect the Ethernet cable to its terminal. 11.7 Switching on - After making all electrical connections, switch on the entrance and exit unit by fl ipping the switch on the LH side of the unit.
  • Page 31: Manned Pay Station - Installation

    Declaration of conformity Declaration - Came Cancelli Automatici S.p.A. declares that this device complies with the essential requirements and other relevant provisions established in 2004/108/CE and 2006/95/CE. Reference code for requesting a true copy: DDF E F003 (automatic pay station)
  • Page 32 HR • Za sve dodatne informacije o poduzeću, proizvodima i tehničkoj podršci: UK • Для отримання будь-якої іншої інформації про компанію, продукцію та технічну підтримку: www. came.com www. came.com CAME Cancelli Automatici S.p.a. CAME Cancelli Automatici S.p.a. Via Martiri Della Libertà, 15 31030 Dosson Di Casier...