The ICS-10X's "telnet server mode"--if the user used the MS-DOS telnet command it will
show double character. So the user can use other Telnet software like: "putty" or "NetTerm".
Example 1: Telnet Command in Windows Platform
Figure 4-38 Telnet Server Configuration screen
The TCP port that ICS-10X uses to listen to connections and that other device
must use to contact ICS-10X. To avoid conflicts with well known TCP ports, the
default is set to "1024".
Use the parameter to set an inactive timeout. The unit drops the connection if
there is no activity on the serial line before the set time expires. To disable the
inactive timeout enter "0".
Figure 4-39 Example Telnet Server