Solution filter cleaning

1
Drive the machine on a level floor.
2
Turn the ignition key to "0"
3
Close the solution valve (A) under the machine, behind the right rear wheel. The valve (A) is closed
when it is in the position (B) and it is open when it is in the position (C)
4
Remove the transparent cup (D), recover the gasket (E), then remove the filter strainer (F) under the
machine, in front of the right rear wheel. Clean them with water and install them on the support (G).
Note:
The filter strainer (F) must be correctly positioned on the housing of the support (G).
5
Open the valve (A)
C
A
B
G
F
E
D
Solution System