PARTS DESCRIPTION

Cover
Body
Connector
DIP Switch
Operation LED
Pattern Width
Adjustment
2
PRECAUTIONS
This mark indicates details regarding handling
Warning:
which, if ignored, may result in death or injury.
This mark indicates a prohibition.
Caution: Observe following instructions to avoid any mulfunction, electric leakage and damage to the unit.
Do not mount higher than 3m.
Do not mount where rain or snow will fall directly on the unit.
The unit may detect other than human body in following cases.
Rain or snow falling on
the detection area.
DA-303S
Base
Sensitivity
Detection Window
Do not leave any objects which may
move in the direction pattern.
In case mounting in such place, use
wateproof cover (option).
Steam or oily smoke covering
the detection area
(Color : Silver)
Mounting screws (2 pcs)
This mark indicates details regarding handling
which, if ignored, may result in delay in
Caution:
reporting attributable to false or missed alarms.
This mark indicates the points of which the user should
be aware.
Avoid mounting in a place with vibration.
Use the unit with auxiliary sensor.
Putting any objects in the detection area.
Cats and dogs entering detection area.
< Accessories >
Connection Cable
(1.5m)
Mounting Template
Instruction manual
Do not mount in a place where
reflection of sunlight will shine on the
unit.

Advertisement

loading

Summary of Contents for Takex DA-303S

  • Page 1: Parts Description

    DA-303S (Color : Silver) Active Infrared Motion & Presence Sensor for Automatic Door Control / Instruction Manual Thank you for purchasing this product. Before using the product, please read this instruction manual carefully to ensure correct operation. PARTS DESCRIPTION Cover <...
  • Page 2: Dip Switch Settings

    MOUNTING AND WIRING To avoid electric shock or damage to the unit, mount the unit in a place where no other devices or Warning: wiring are already installed Remove cover. Remove body and mounting screws Using supplied from base. mounting template, drill mounting and wiring holes.
  • Page 3 ADJUSTING DETECTION PATTERN Caution: Adjust patter depth suitable for required operation. Caution: Adjust pattern depth not to cover door area. Body angle adjustment Detection depth 0°or +5°is selectable by changing body angle. * 2 patterns ( 0° or +5°) selectable Pattern Depth Adjustment Adjustable with "Pattern Depth "...
  • Page 4: Troubleshooting

    Limited Warranty : TAKEX products are warranted to be free from defects in material and workmanship for 12 months from original date of shipment. Our warranty does not cover damage or failure caused by natural disasters, abuse, misuse, abnormal usage, faulty installation, improper maintenance or any repairs other than those provided by TAKEX.