3
MOUNTING AND WIRING
To avoid electric shock or damage to the unit, mount the unit in a place where no other devices or
Warning:
wiring are already installed
Using supplied
mounting template,
drill mounting and
wiring holes.
Mount base with mounting
screws.
Adjust settings following :
DIP Switch settings
Adjusting Detection Pattern
Adjusting Sensitivity
Verification of Operation
4
DIP SWITCH SETTINGS
Caution:
Select settings suitable for required operation.
②Presence Timer
①Pattern Depth
☆
2 sec
☆
4 R
10 sec
3 R
2 R
60 sec
∞
1 R
When DIP switch settings are adjusted while power
is on, the unit will restart after approx. 6 sec.
5
DETECTION AFTER POWER ON / RESTART
Caution:
Before power-on, finish wiring the unit and door controller.
After power-on or restart,
- when there is any moving object in detection pattern, moving object detection is activated.
- when there is no moving object in detection pattern, stationary object detection is activated.
After power-on
/ restart
Be sure to turn the power off before making following job.
When power is on, detection continues during presence timer setting.
Put/remove door
mat /scraper in
detection pattern.
Mount body to base.
Place connector in holder.
Factory set
③Frequency
④Env. Level. Adj.
☆
☆
Normal
A
Level 1
B
C
Level 2
D
Level 3
[ Approx. 2 sec ]
Moving Object
Detection
Adjust body angle.
Remove cover.
Connect wiring and push connector.
* Non-polarity for both cables
Cable from unit
①
Pattern Depth (Rows):
☆
Patten Depth is adjustable from 1 to 4 rows.
②
Presence Timer :
The unit detects a stationary object following presence timer
setting to 2 sec, 10 sec. 60 sec and ∞. With ∞ setting, 1st
and 2nd rows are set to ∞ and 3rd and 4th rows to 2 sec.
③
Frequency :
Select different frequency to avoid interference by other
sensors with different depth pattern setting.
④
Environmental level adjustment :
Select level 1 to 3, depending on frequency of malfunction caused
by rain, wet floor, snow fall, snow cover, insects, distorted mounting
part for opening/closing of door, etc. The unit operates with less
malfunction but becomes less sensitive to human body with higher
level setting.
[ Approx. 7 sec ]
No Moving Object
Stationary Object
Detection
Any Moving Object
Moving Object
Detection
Adjust pattern width.
②
Remove body and mounting screws
from base.
Connection Cable
Yellow (Output)
Gray (Power)
Replace cover.
Do not move body when
placing cover.
[ Approx. 7 sec ]
No Moving Object
Stationary Object
Removal of
moving object
Adjust sensitivity.
Detection