Download Print this page

Dip Switch Settings - Takex DA-303S Instruction Manual

Active infrared motion & presence sensor for automatic door control

Advertisement

3
MOUNTING AND WIRING
To avoid electric shock or damage to the unit, mount the unit in a place where no other devices or
Warning:
wiring are already installed
Using supplied
mounting template,
drill mounting and
wiring holes.
Mount base with mounting
screws.
Adjust settings following :

DIP Switch settings

Adjusting Detection Pattern
Adjusting Sensitivity
Verification of Operation
4
DIP SWITCH SETTINGS
Caution:
Select settings suitable for required operation.
②Presence Timer
①Pattern Depth
2 sec
4 R
10 sec
3 R
2 R
60 sec
1 R
When DIP switch settings are adjusted while power
is on, the unit will restart after approx. 6 sec.
5
DETECTION AFTER POWER ON / RESTART
Caution:
Before power-on, finish wiring the unit and door controller.
After power-on or restart,
- when there is any moving object in detection pattern, moving object detection is activated.
- when there is no moving object in detection pattern, stationary object detection is activated.
After power-on
/ restart
Be sure to turn the power off before making following job.
When power is on, detection continues during presence timer setting.
Put/remove door
mat /scraper in
detection pattern.
Mount body to base.
Place connector in holder.
Factory set
③Frequency
④Env. Level. Adj.
Normal
A
Level 1
B
C
Level 2
D
Level 3
[ Approx. 2 sec ]
Moving Object
Detection
Adjust body angle.
Remove cover.
Connect wiring and push connector.
* Non-polarity for both cables
Cable from unit
Pattern Depth (Rows):
Patten Depth is adjustable from 1 to 4 rows.
Presence Timer :
The unit detects a stationary object following presence timer
setting to 2 sec, 10 sec. 60 sec and ∞. With ∞ setting, 1st
and 2nd rows are set to ∞ and 3rd and 4th rows to 2 sec.
Frequency :
Select different frequency to avoid interference by other
sensors with different depth pattern setting.
Environmental level adjustment :
Select level 1 to 3, depending on frequency of malfunction caused
by rain, wet floor, snow fall, snow cover, insects, distorted mounting
part for opening/closing of door, etc. The unit operates with less
malfunction but becomes less sensitive to human body with higher
level setting.
[ Approx. 7 sec ]
No Moving Object
Stationary Object
Detection
Any Moving Object
Moving Object
Detection
Adjust pattern width.
Remove body and mounting screws
from base.
Connection Cable
Yellow (Output)
Gray (Power)
Replace cover.
Do not move body when
placing cover.
[ Approx. 7 sec ]
No Moving Object
Stationary Object
Removal of
moving object
Adjust sensitivity.
Detection

Advertisement